.. _minio-erasure-coding:
|
||
|
||
==============
|
||
Erasure Coding
|
||
==============
|
||
|
||
.. default-domain:: minio
|
||
|
||
.. contents:: Table of Contents
|
||
:local:
|
||
:depth: 2
|
||
|
||
MinIO Erasure Coding is a data redundancy and availability feature that allows
|
||
MinIO deployments to automatically reconstruct objects on-the-fly despite the
|
||
loss of multiple drives or nodes in the cluster. Erasure Coding provides
|
||
object-level healing with less overhead than adjacent technologies such as
|
||
RAID or replication.
|
||
|
||
MinIO splits each new object into data and parity blocks, where parity blocks
|
||
support reconstruction of missing or corrupted data blocks. MinIO writes these
|
||
blocks to a single :ref:`erasure set <minio-ec-erasure-set>` in the deployment.
|
||
Since erasure set drives are striped across the deployment, a given node
|
||
typically contains only a portion of data or parity blocks for each object.
|
||
MinIO can therefore tolerate the loss of multiple drives or nodes in the
|
||
deployment depending on the configured parity and deployment topology.
|
||
|
||
.. image:: /images/erasure-code.jpg
|
||
:width: 600px
|
||
:alt: MinIO Erasure Coding example
|
||
:align: center
|
||
|
||
At maximum parity, MinIO can tolerate the loss of up to half the drives per
|
||
erasure set (``N/2-1``) and still perform read and write operations. MinIO
|
||
defaults to 4 parity blocks per object with tolerance for the loss of 4 drives
|
||
per erasure set. For more complete information on selecting erasure code parity,
|
||
see :ref:`minio-ec-parity`.
|
||
|
||
Erasure coding is a core requirement for the following MinIO features:
|
||
|
||
- :ref:`Object Versioning <minio-bucket-versioning>`
|
||
- :ref:`Server-Side Replication <minio-bucket-replication>`
|
||
- :ref:`Write-Once Read-Many Locking <minio-bucket-locking>`
|
||
|
||
Use the MinIO `Erasure Code Calculator
|
||
<https://min.io/product/erasure-code-calculator?ref=docs>`__ when planning and
|
||
designing your MinIO deployment to explore the effect of erasure code settings
|
||
on your intended topology.
|
||
|
||
Zero-Parity Deployments
|
||
-----------------------
|
||
|
||
Starting with :minio-release:`RELEASE.2022-06-02T02-11-04Z`, MinIO supports a Single-Node Single-Drive (SNSD) topology with a zero-parity erasure coding backend.
|
||
|
||
Erasure Coding protections do not apply to the zero-parity backend of |SNSD| deployments.
|
||
Zero-parity deployments depend on the underlying storage for resiliency and availability.
|
||
|
||
.. _minio-ec-erasure-set:
|
||
|
||
Erasure Sets
|
||
------------
|
||
|
||
An *Erasure Set* is a set of drives in a MinIO deployment that support Erasure
|
||
Coding. MinIO evenly distributes object data and parity blocks among the drives
|
||
in the Erasure Set. MinIO randomly and uniformly distributes the data and parity
|
||
blocks across drives in the erasure set with *no overlap*. Each unique object
|
||
has no more than one data or parity block per drive in the set.
|
||
|
||
MinIO calculates the number and size of *Erasure Sets* by dividing the total
|
||
number of drives in the :ref:`Server Pool <minio-intro-server-pool>` into sets
|
||
consisting of between 4 and 16 drives each.
|
||
|
||
Use the MinIO
|
||
`Erasure Coding Calculator <https://min.io/product/erasure-code-calculator>`__
|
||
to determine the optimal erasure set size for your preferred MinIO topology.
|
||
|
||
.. _minio-ec-parity:
|
||
|
||
Erasure Code Parity (``EC:N``)
|
||
------------------------------
|
||
|
||
MinIO uses a Reed-Solomon algorithm to split objects into data and parity blocks
|
||
based on the :ref:`Erasure Set <minio-ec-erasure-set>` size in the deployment.
|
||
For a given erasure set of size ``M``, MinIO splits objects into ``N`` parity
|
||
blocks and ``M-N`` data blocks.
|
||
|
||
MinIO uses the ``EC:N`` notation to refer to the number of parity blocks (``N``)
|
||
in the deployment. MinIO defaults to ``EC:4`` or 4 parity blocks per object.
|
||
MinIO uses the same ``EC:N`` value for all erasure sets and
|
||
:ref:`server pools <minio-intro-server-pool>` in the deployment.
|
||
|
||
MinIO can tolerate the loss of up to ``N`` drives per erasure set and
|
||
continue performing read and write operations ("quorum"). If ``N`` is equal
|
||
to exactly 1/2 the drives in the erasure set, MinIO write quorum requires
|
||
``N+1`` drives to avoid data inconsistency ("split-brain").
|
||
|
||
Setting the parity for a deployment is a balance between availability
|
||
and total usable storage. Higher parity values increase resiliency to drive
|
||
or node failure at the cost of usable storage, while lower parity provides
|
||
maximum storage with reduced tolerance for drive/node failures.
|
||
Use the MinIO `Erasure Code Calculator
|
||
<https://min.io/product/erasure-code-calculator?ref=docs>`__ to explore the
|
||
effect of parity on your planned cluster deployment.
|
||
|
||
The following table lists the outcome of varying erasure code parity levels on
|
||
a MinIO deployment consisting of 1 node and 16 1TB drives:
|
||
|
||
.. list-table:: Outcome of Parity Settings on a 16 Drive MinIO Cluster
|
||
:header-rows: 1
|
||
:widths: 20 20 20 20 20
|
||
:width: 100%
|
||
|
||
* - Parity
|
||
- Total Storage
|
||
- Storage Ratio
|
||
- Minimum Drives for Read Operations
|
||
- Minimum Drives for Write Operations
|
||
|
||
* - ``EC: 4`` (Default)
|
||
- 12 Tebibytes
|
||
- 0.750
|
||
- 12
|
||
- 12
|
||
|
||
* - ``EC: 6``
|
||
- 10 Tebibytes
|
||
- 0.625
|
||
- 10
|
||
- 10
|
||
|
||
* - ``EC: 8``
|
||
- 8 Tebibytes
|
||
- 0.500
|
||
- 8
|
||
- 9
|
||
|
||
.. _minio-ec-storage-class:
|
||
|
||
Storage Classes
|
||
~~~~~~~~~~~~~~~
|
||
|
||
MinIO supports storage classes with Erasure Coding to allow applications to
|
||
specify per-object :ref:`parity <minio-ec-parity>`. Each storage class specifies
|
||
a ``EC:N`` parity setting to apply to objects created with that class.
|
||
|
||
MinIO storage classes are *distinct* from Amazon Web Services
|
||
:s3-docs:`storage classes <storage-class-intro.html>`. MinIO storage classes
|
||
define *parity settings per object*, while AWS storage classes define *storage
|
||
tiers per object*.
|
||
|
||
MinIO provides the following two storage classes:
|
||
|
||
.. tab-set::
|
||
|
||
.. tab-item:: STANDARD
|
||
|
||
The ``STANDARD`` storage class is the default class for all objects.
|
||
MinIO sets the ``STANDARD`` parity based on the number of volumes
|
||
in the Erasure Set:
|
||
|
||
.. list-table::
|
||
:header-rows: 1
|
||
:widths: 30 70
|
||
:width: 100%
|
||
|
||
* - Erasure Set Size
|
||
- Default Parity (EC:N)
|
||
|
||
* - 5 or Fewer
|
||
- EC:2
|
||
|
||
* - 6 - 7
|
||
- EC:3
|
||
|
||
* - 8 or more
|
||
- EC:4
|
||
|
||
You can override the default ``STANDARD`` parity using either:
|
||
|
||
- The :envvar:`MINIO_STORAGE_CLASS_STANDARD` environment variable, *or*
|
||
- The :mc:`mc admin config` command to modify the
|
||
``storage_class.standard`` configuration setting.
|
||
|
||
The maximum value is half of the total drives in the
|
||
:ref:`Erasure Set <minio-ec-erasure-set>`. The minimum value is ``2``.
|
||
|
||
``STANDARD`` parity *must* be greater than or equal to
|
||
``REDUCED_REDUNDANCY``. If ``REDUCED_REDUNDANCY`` is unset, ``STANDARD``
|
||
parity *must* be greater than 2.
|
||
|
||
.. tab-item:: REDUCED_REDUNDANCY
|
||
|
||
The ``REDUCED_REDUNDANCY`` storage class allows creating objects with
|
||
lower parity than ``STANDARD``. ``REDUCED_REDUNDANCY`` requires
|
||
*at least* 5 drives in the MinIO deployment.
|
||
|
||
MinIO sets the ``REDUCED_REDUNDANCY`` parity to ``EC:2`` by default.
|
||
You can override ``REDUCED_REDUNDANCY`` storage class parity using
|
||
either:
|
||
|
||
- The :envvar:`MINIO_STORAGE_CLASS_RRS` environment variable, *or*
|
||
- The :mc:`mc admin config` command to modify the
|
||
``storage_class.rrs`` configuration setting.
|
||
|
||
``REDUCED_REDUNDANCY`` parity *must* be less than or equal to
|
||
``STANDARD``.
|
||
|
||
MinIO references the ``x-amz-storage-class`` header in request metadata for
|
||
determining which storage class to assign an object. The specific syntax
|
||
or method for setting headers depends on your preferred method for
|
||
interfacing with the MinIO server.
|
||
|
||
- For the :mc:`mc` command line tool, certain commands include a specific
|
||
option for setting the storage class. For example, the :mc:`mc cp` command
|
||
has the :mc-cmd:`~mc cp storage-class` option for specifying the
|
||
storage class to assign to the object being copied.
|
||
|
||
- For MinIO SDKs, the ``S3Client`` object has specific methods for setting
|
||
request headers. For example, the ``minio-go`` SDK ``S3Client.PutObject``
|
||
method takes a ``PutObjectOptions`` data structure as a parameter.
|
||
The ``PutObjectOptions`` data structure includes the ``StorageClass``
|
||
option for specifying the storage class to assign to the object being
|
||
created.
|
||
|
||
|
||
.. _minio-ec-bitrot-protection:
|
||
|
||
BitRot Protection
|
||
-----------------
|
||
|
||
.. TODO- ReWrite w/ more detail.
|
||
|
||
Silent data corruption or bitrot is a serious problem faced by disk drives
|
||
resulting in data getting corrupted without the user’s knowledge. The reasons
|
||
are manifold (ageing drives, current spikes, bugs in disk firmware, phantom
|
||
writes, misdirected reads/writes, driver errors, accidental overwrites) but the
|
||
result is the same - compromised data.
|
||
|
||
MinIO’s optimized implementation of the HighwayHash algorithm ensures that it
|
||
will never read corrupted data - it captures and heals corrupted objects on the
|
||
fly. Integrity is ensured from end to end by computing a hash on READ and
|
||
verifying it on WRITE from the application, across the network and to the
|
||
memory/drive. The implementation is designed for speed and can achieve hashing
|
||
speeds over 10 GB/sec on a single core on Intel CPUs.
|