Updates `mc` reference docs for several releases of the MinIO Client. - Adds missing flags to `mc admin trace` - Updates `disk` -> `drive` throughout the docs, but not in all cases. - Adds `--airgap flag` to `mc support profile` and `mc support perf` commands. - Updates the flags for `mc ilm add` command - Adds `mc license unregister` command. Closes #571 Closes #614 Closes #627 Closes #633
69 lines
3.0 KiB
ReStructuredText
69 lines
3.0 KiB
ReStructuredText
.. _minio-restore-hardware-failure:
|
|
|
|
==============================
|
|
Recover after Hardware Failure
|
|
==============================
|
|
|
|
.. default-domain:: minio
|
|
|
|
.. contents:: Table of Contents
|
|
:local:
|
|
:depth: 1
|
|
|
|
Distributed MinIO deployments rely on :ref:`Erasure Coding
|
|
<minio-erasure-coding>` to provide built-in tolerance for multiple drive or node
|
|
failures. Depending on the deployment topology and the selected erasure code
|
|
parity, MinIO can tolerate the loss of up to half the drives or nodes in the
|
|
deployment while maintaining read access ("read quorum") to objects.
|
|
|
|
The following table lists the typical types of failure in a MinIO deployment
|
|
and links to procedures for recovering from each:
|
|
|
|
.. list-table::
|
|
:header-rows: 1
|
|
:widths: 30 70
|
|
:width: 100%
|
|
|
|
* - Failure Type
|
|
- Description
|
|
|
|
* - :ref:`Drive Failure <minio-restore-hardware-failure-drive>`
|
|
- MinIO supports hot-swapping failed drives with new healthy drives.
|
|
|
|
* - :ref:`Node Failure <minio-restore-hardware-failure-node>`
|
|
- MinIO detects when a node rejoins the deployment and begins proactively healing the node shortly after it is joined back to the cluster healing data previously stored on that node.
|
|
|
|
* - :ref:`Site Failure <minio-restore-hardware-failure-site>`
|
|
- MinIO Site Replication supports complete resynchronization of buckets, objects, and replication-eligible configuration settings after total site loss.
|
|
|
|
Since MinIO can operate in a degraded state without significant performance
|
|
loss, administrators can schedule hardware replacement in proportion to the rate
|
|
of hardware failure. "Normal" failure rates (single drive or node failure) may
|
|
allow for a more reasonable replacement timeframe, while "critical" failure
|
|
rates (multiple drives or nodes) may require a faster response.
|
|
|
|
For nodes with one or more drives that are either partially failed or operating
|
|
in a degraded state (increasing drive errors, SMART warnings, timeouts in MinIO
|
|
logs, etc.), you can safely unmount the drive *if* the cluster has sufficient
|
|
remaining healthy drives to maintain
|
|
:ref:`read and write quorum <minio-ec-parity>`. Missing drives are less
|
|
disruptive to the deployment than drives that are reliably producing read and
|
|
write errors.
|
|
|
|
.. admonition:: MinIO Professional Support
|
|
:class: note
|
|
|
|
`MinIO SUBNET <https://min.io/pricing?jmp=docs>`__ users can
|
|
`log in <https://subnet.min.io/>`__ and create a new issue related to drive, node, or site failures.
|
|
Coordination with MinIO Engineering via SUBNET can ensure successful recovery operations of production MinIO deployments, including root-cause analysis, and health diagnostics.
|
|
|
|
Community users can seek support on the `MinIO Community Slack <https://slack.min.io>`__.
|
|