Fix LOCK_TIMEOUT handling in slotsync worker.

Previously, the slotsync worker relied on SIGINT for graceful shutdown
during promotion. However, SIGINT is also used by the LOCK_TIMEOUT handler
to cancel queries. Since the slotsync worker can lock catalog tables while
parsing libpq tuples, this overlap caused it to ignore LOCK_TIMEOUT
signals and potentially wait indefinitely on locks.

This patch replaces the slotsync worker's SIGINT handler with
StatementCancelHandler to correctly process query-cancel interrupts.
Additionally, the startup process now uses SIGUSR1 to signal the slotsync
worker to stop during promotion. The worker exits after detecting that the
shared memory flag stopSignaled is set.

Author: Hou Zhijie <houzj.fnst@fujitsu.com>
Reviewed-by: shveta malik <shveta.malik@gmail.com>
Reviewed-by: Chao Li <li.evan.chao@gmail.com>
Reviewed-by: Amit Kapila <amit.kapila16@gmail.com>
Backpatch-through: 17, here it was introduced
Discussion: https://postgr.es/m/TY4PR01MB169078F33846E9568412D878C94A2A@TY4PR01MB16907.jpnprd01.prod.outlook.com
This commit is contained in:
Amit Kapila
2025-12-09 07:25:20 +00:00
parent 2268f2b91b
commit 04396eacd3

View File

@@ -1254,10 +1254,10 @@ ProcessSlotSyncInterrupts(void)
{
CHECK_FOR_INTERRUPTS();
if (ShutdownRequestPending)
if (SlotSyncCtx->stopSignaled)
{
ereport(LOG,
errmsg("replication slot synchronization worker is shutting down on receiving SIGINT"));
errmsg("replication slot synchronization worker is shutting down because promotion is triggered"));
proc_exit(0);
}
@@ -1488,7 +1488,7 @@ ReplSlotSyncWorkerMain(const void *startup_data, size_t startup_data_len)
/* Setup signal handling */
pqsignal(SIGHUP, SignalHandlerForConfigReload);
pqsignal(SIGINT, SignalHandlerForShutdownRequest);
pqsignal(SIGINT, StatementCancelHandler);
pqsignal(SIGTERM, die);
pqsignal(SIGFPE, FloatExceptionHandler);
pqsignal(SIGUSR1, procsignal_sigusr1_handler);
@@ -1595,7 +1595,8 @@ ReplSlotSyncWorkerMain(const void *startup_data, size_t startup_data_len)
/*
* The slot sync worker can't get here because it will only stop when it
* receives a SIGINT from the startup process, or when there is an error.
* receives a stop request from the startup process, or when there is an
* error.
*/
Assert(false);
}
@@ -1680,8 +1681,12 @@ ShutDownSlotSync(void)
SpinLockRelease(&SlotSyncCtx->mutex);
/*
* Signal slotsync worker if it was still running. The worker will stop
* upon detecting that the stopSignaled flag is set to true.
*/
if (worker_pid != InvalidPid)
kill(worker_pid, SIGINT);
kill(worker_pid, SIGUSR1);
/* Wait for slot sync to end */
for (;;)