1
0
mirror of https://github.com/inexio/thola.git synced 2026-10-24 03:08:55 +03:00
Files
thola/internal/request/check_ups_process.go
2021-12-02 18:30:03 +01:00

131 lines
5.5 KiB
Go

//go:build !client
// +build !client
package request
import (
"context"
"github.com/inexio/go-monitoringplugin"
"github.com/inexio/thola/internal/utility"
)
func (r *CheckUPSRequest) process(ctx context.Context) (Response, error) {
r.init()
com, err := GetCommunicator(ctx, r.BaseRequest)
if r.mon.UpdateStatusOnError(err, monitoringplugin.UNKNOWN, "error while getting communicator", true) {
return &CheckResponse{r.mon.GetInfo()}, nil
}
readUPSResponse, err := com.GetUPSComponent(ctx)
if r.mon.UpdateStatusOnError(err, monitoringplugin.UNKNOWN, "error while reading ups", true) {
return &CheckResponse{r.mon.GetInfo()}, nil
}
if r.mon.UpdateStatusOnError(err, monitoringplugin.UNKNOWN, "error while processing read ups request", true) {
r.mon.PrintPerformanceData(false)
return &CheckResponse{r.mon.GetInfo()}, nil
}
if readUPSResponse.AlarmLowVoltageDisconnect != nil {
err := r.mon.AddPerformanceDataPoint(monitoringplugin.NewPerformanceDataPoint("alarm_low_voltage_disconnect", *readUPSResponse.AlarmLowVoltageDisconnect))
if r.mon.UpdateStatusOnError(err, monitoringplugin.UNKNOWN, "error while adding performance data point", true) {
r.mon.PrintPerformanceData(false)
return &CheckResponse{r.mon.GetInfo()}, nil
}
}
if readUPSResponse.BatteryAmperage != nil {
err := r.mon.AddPerformanceDataPoint(monitoringplugin.NewPerformanceDataPoint("batt_amperage", *readUPSResponse.BatteryAmperage))
if r.mon.UpdateStatusOnError(err, monitoringplugin.UNKNOWN, "error while adding performance data point", true) {
r.mon.PrintPerformanceData(false)
return &CheckResponse{r.mon.GetInfo()}, nil
}
}
if readUPSResponse.BatteryRemainingTime != nil {
err := r.mon.AddPerformanceDataPoint(monitoringplugin.NewPerformanceDataPoint("batt_remaining_time", *readUPSResponse.BatteryRemainingTime))
if r.mon.UpdateStatusOnError(err, monitoringplugin.UNKNOWN, "error while adding performance data point", true) {
r.mon.PrintPerformanceData(false)
return &CheckResponse{r.mon.GetInfo()}, nil
}
}
if readUPSResponse.BatteryCapacity != nil {
err := r.mon.AddPerformanceDataPoint(monitoringplugin.NewPerformanceDataPoint("batt_capacity", *readUPSResponse.BatteryCapacity))
if r.mon.UpdateStatusOnError(err, monitoringplugin.UNKNOWN, "error while adding performance data point", true) {
r.mon.PrintPerformanceData(false)
return &CheckResponse{r.mon.GetInfo()}, nil
}
}
if readUPSResponse.BatteryCurrent != nil {
err := r.mon.AddPerformanceDataPoint(
monitoringplugin.NewPerformanceDataPoint("batt_current", *readUPSResponse.BatteryCurrent).
SetThresholds(r.BatteryCurrentThresholds))
if r.mon.UpdateStatusOnError(err, monitoringplugin.UNKNOWN, "error while adding performance data point", true) {
r.mon.PrintPerformanceData(false)
return &CheckResponse{r.mon.GetInfo()}, nil
}
}
if readUPSResponse.BatteryTemperature != nil {
err := r.mon.AddPerformanceDataPoint(
monitoringplugin.NewPerformanceDataPoint("batt_temperature", *readUPSResponse.BatteryTemperature).
SetThresholds(r.BatteryTemperatureThresholds))
if r.mon.UpdateStatusOnError(err, monitoringplugin.UNKNOWN, "error while adding performance data point", true) {
r.mon.PrintPerformanceData(false)
return &CheckResponse{r.mon.GetInfo()}, nil
}
}
if readUPSResponse.BatteryVoltage != nil {
err := r.mon.AddPerformanceDataPoint(monitoringplugin.NewPerformanceDataPoint("batt_voltage", *readUPSResponse.BatteryVoltage))
if r.mon.UpdateStatusOnError(err, monitoringplugin.UNKNOWN, "error while adding performance data point", true) {
r.mon.PrintPerformanceData(false)
return &CheckResponse{r.mon.GetInfo()}, nil
}
}
if readUPSResponse.CurrentLoad != nil {
err := r.mon.AddPerformanceDataPoint(
monitoringplugin.NewPerformanceDataPoint("current_load", *readUPSResponse.CurrentLoad).
SetThresholds(r.CurrentLoadThresholds))
if r.mon.UpdateStatusOnError(err, monitoringplugin.UNKNOWN, "error while adding performance data point", true) {
r.mon.PrintPerformanceData(false)
return &CheckResponse{r.mon.GetInfo()}, nil
}
}
if readUPSResponse.MainsVoltageApplied != nil {
err := r.mon.AddPerformanceDataPoint(monitoringplugin.NewPerformanceDataPoint("mains_voltage_applied", utility.IfThenElse(*readUPSResponse.MainsVoltageApplied, 1, 0)))
if r.mon.UpdateStatusOnError(err, monitoringplugin.UNKNOWN, "error while adding performance data point", true) {
r.mon.PrintPerformanceData(false)
return &CheckResponse{r.mon.GetInfo()}, nil
}
r.mon.UpdateStatusIfNot(*readUPSResponse.MainsVoltageApplied, monitoringplugin.CRITICAL, "Mains voltage is not applied")
}
if readUPSResponse.RectifierCurrent != nil {
err := r.mon.AddPerformanceDataPoint(
monitoringplugin.NewPerformanceDataPoint("rectifier_current", *readUPSResponse.RectifierCurrent).
SetThresholds(r.RectifierCurrentThresholds))
if r.mon.UpdateStatusOnError(err, monitoringplugin.UNKNOWN, "error while adding performance data point", true) {
r.mon.PrintPerformanceData(false)
return &CheckResponse{r.mon.GetInfo()}, nil
}
}
if readUPSResponse.SystemVoltage != nil {
err := r.mon.AddPerformanceDataPoint(
monitoringplugin.NewPerformanceDataPoint("sys_voltage", *readUPSResponse.SystemVoltage).
SetThresholds(r.SystemVoltageThresholds))
if r.mon.UpdateStatusOnError(err, monitoringplugin.UNKNOWN, "error while adding performance data point", true) {
r.mon.PrintPerformanceData(false)
return &CheckResponse{r.mon.GetInfo()}, nil
}
}
return &CheckResponse{r.mon.GetInfo()}, nil
}