DOCS-369: Fix incorrect erasure code parity calculation

This commit is contained in:
ravindk89
2021-09-08 21:05:20 -04:00
committed by Ravind Kumar
parent a4909655b0
commit 4308f69541
4 changed files with 86 additions and 108 deletions

View File

@ -16,84 +16,48 @@ loss of multiple drives or nodes in the cluster. Erasure Coding provides
object-level healing with less overhead than adjacent technologies such as object-level healing with less overhead than adjacent technologies such as
RAID or replication. RAID or replication.
Erasure Coding splits objects into data and parity blocks, where parity blocks MinIO splits each new object into data and parity blocks, where parity blocks
support reconstruction of missing or corrupted data blocks. MinIO distributes support reconstruction of missing or corrupted data blocks. MinIO writes these
both data and parity blocks across :mc:`minio server` nodes and drives in an blocks to a single :ref:`erasure set <minio-ec-erasure-set>` in the deployment.
:ref:`Erasure Set <minio-ec-erasure-set>`. Depending on the configured parity, Since erasure set drives are striped across the deployment, a given node
number of nodes, and number of drives per node in the Erasure Set, MinIO can typically contains only a portion of data or parity blocks for each object.
tolerate the loss of up to half (``N/2``) of drives and still retrieve stored MinIO can therefore tolerate the loss of multiple drives or nodes in the
objects. deployment depending on the configured parity and deployment topology.
For example, consider a small-scale MinIO deployment consisting of a .. image:: /images/erasure-code.jpg
single :ref:`Server Pool <minio-intro-server-pool>` with 4 :mc:`minio server` :width: 600px
nodes. Each node in the deployment has 4 locally attached ``1Ti`` drives for :alt: MinIO Erasure Coding example
a total of 16 drives. :align: center
MinIO creates :ref:`Erasure Sets <minio-ec-erasure-set>` by dividing the total At maximum parity, MinIO can tolerate the loss of up to half the drives per
number of drives in the deployment into sets consisting of between 4 and 16 erasure set (``N/2-1``) and still perform read and write operations. MinIO
drives each. In the example deployment, the largest possible Erasure Set size defaults to 4 parity blocks per object with tolerance for the loss of 4 drives
that evenly divides into the total number of drives is ``16``. per erasure set. For more complete information on selecting erasure code parity,
see :ref:`minio-ec-parity`.
MinIO uses a Reed-Solomon algorithm to split objects into data and parity blocks Erasure coding requires a minimum of 4 drives is only available with
based on the size of the Erasure Set. MinIO then uniformly distributes the :ref:`distributed <minio-installation-comparison>` MinIO deployments. Erasure
data and parity blocks across the Erasure Set drives such that each drive coding is is a core requirement for the following MinIO features:
in the set contains no more than one block per object. MinIO uses
the ``EC:N`` notation to refer to the number of parity blocks (``N``) in the
Erasure Set.
The number of parity blocks in a deployment controls the deployment's relative - :ref:`Object Versioning <minio-bucket-versioning>`
data redundancy. Higher levels of parity allow for higher tolerance of drive - :ref:`Server-Side Replication <minio-bucket-replication>`
loss at the cost of total available storage. For example, using EC:4 in our - :ref:`Write-Once Read-Many Locking <minio-bucket-locking>`
example deployment results in 12 data blocks and 4 parity blocks. The parity
blocks take up some portion of space in the deployment, reducing total storage.
*However*, the parity blocks allow MinIO to reconstruct the object with only
8 data blocks, increasing resilience to data corruption or loss.
The following table lists the outcome of varying EC levels on the example Use the MinIO `Erasure Code Calculator
deployment: <https://min.io/product/erasure-code-calculator?ref=docs>`__ when planning and
designing your MinIO deployment to explore the effect of erasure code settings
.. list-table:: Outcome of Parity Settings on a 16 Drive MinIO Cluster on your intended topology.
:header-rows: 1
:widths: 20 20 20 20 20
:width: 100%
* - Parity
- Total Storage
- Storage Ratio
- Minimum Drives for Read Operations
- Minimum Drives for Write Operations
* - ``EC: 4`` (Default)
- 12 Tebibytes
- 0.750
- 12
- 13
* - ``EC: 6``
- 10 Tebibytes
- 0.625
- 10
- 11
* - ``EC: 8``
- 8 Tebibytes
- 0.500
- 8
- 9
- For more information on Erasure Sets, see :ref:`minio-ec-erasure-set`.
- For more information on selecting Erasure Code Parity, see
:ref:`minio-ec-parity`
.. _minio-ec-erasure-set: .. _minio-ec-erasure-set:
Erasure Sets Erasure Sets
------------ ------------
An *Erasure Set* is a set of drives in a MinIO deployment that support An *Erasure Set* is a set of drives in a MinIO deployment that support Erasure
Erasure Coding. MinIO evenly distributes object data and parity blocks among Coding. MinIO evenly distributes object data and parity blocks among the drives
the drives in the Erasure Set. in the Erasure Set. MinIO randomly and uniformly distributes the data and parity
blocks across drives in the erasure set with *no overlap*. Each unique object
has no more than one data or parity block per drive in the set.
MinIO calculates the number and size of *Erasure Sets* by dividing the total MinIO calculates the number and size of *Erasure Sets* by dividing the total
number of drives in the :ref:`Server Pool <minio-intro-server-pool>` into sets number of drives in the :ref:`Server Pool <minio-intro-server-pool>` into sets
@ -131,50 +95,59 @@ Erasure Code Parity (``EC:N``)
------------------------------ ------------------------------
MinIO uses a Reed-Solomon algorithm to split objects into data and parity blocks MinIO uses a Reed-Solomon algorithm to split objects into data and parity blocks
based on the size of the Erasure Set. MinIO uses parity blocks to automatically based on the :ref:`Erasure Set <minio-ec-erasure-set>` size in the deployment.
heal damaged or missing data blocks when reconstructing an object. MinIO uses For a given erasure set of size ``M``, MinIO splits objects into ``N`` parity
the ``EC:N`` notation to refer to the number of parity blocks (``N``) in the blocks and ``M-N`` data blocks.
Erasure Set.
MinIO uses a hash of an object's name to determine into which Erasure Set to MinIO uses the ``EC:N`` notation to refer to the number of parity blocks (``N``)
store that object. MinIO always uses that erasure set for objects with a in the deployment. MinIO defaults to ``EC:4`` or 4 parity blocks per object.
matching name. For example, MinIO stores all :ref:`versions MinIO uses the same ``EC:N`` value for all erasure sets and
<minio-bucket-versioning>` of an object in the same Erasure Set. :ref:`server pools <minio-intro-server-pool>` in the deployment.
After MinIO selects an object's Erasure Set, it divides the object based on the MinIO can tolerate the loss of up to ``N`` drives per erasure set and
number of drives in the set and the configured parity. MinIO creates: continue performing read and write operations ("quorum"). If ``N`` is equal
to exactly 1/2 the drives in the erasure set, MinIO write quorum requires
``N+1`` drives to avoid data inconsistency ("split-brain").
- ``(Erasure Set Drives) - EC:N`` Data Blocks, *and* Setting the parity for a deployment is a balance between availability
- ``EC:N`` Parity Blocks. and total usable storage. Higher parity values increase resiliency to drive
or node failure at the cost of usable storage, while lower parity provides
maximum storage with reduced tolerance for drive/node failures.
Use the MinIO `Erasure Code Calculator
<https://min.io/product/erasure-code-calculator?ref=docs>`__ to explore the
effect of parity on your planned cluster deployment.
MinIO randomly and uniformly distributes the data and parity blocks across The following table lists the outcome of varying erasure code parity levels on
drives in the erasure set with *no overlap*. While a drive may contain both data a MinIO deployment consisting of 1 node and 16 1TB drives:
and parity blocks for multiple unique objects, a single unique object has no
more than one block per drive in the set. For versioned objects, MinIO selects
the same drives for both data and parity storage while maintaining zero overlap
on any single drive.
The specified parity for an object also dictates the minimum number of Erasure .. list-table:: Outcome of Parity Settings on a 16 Drive MinIO Cluster
Set drives ("Quorum") required for MinIO to either read or write that object: :header-rows: 1
:widths: 20 20 20 20 20
:width: 100%
.. _minio-read-quorum: * - Parity
- Total Storage
- Storage Ratio
- Minimum Drives for Read Operations
- Minimum Drives for Write Operations
Read Quorum * - ``EC: 4`` (Default)
The minimum number of Erasure Set drives required for MinIO to - 12 Tebibytes
serve read operations. MinIO can automatically reconstruct an object - 0.750
with corrupted or missing data blocks if enough drives are online to - 12
provide Read Quorum for that object. - 12
MinIO Read Quorum is ``DRIVES - (EC:N)``. * - ``EC: 6``
- 10 Tebibytes
- 0.625
- 10
- 10
.. _minio-write-quorum: * - ``EC: 8``
- 8 Tebibytes
Write Quorum - 0.500
The minimum number of Erasure Set drives required for MinIO - 8
to serve write operations. MinIO requires enough available drives to - 9
eliminate the risk of split-brain scenarios.
MinIO Write Quorum is ``(DRIVES - (EC:N)) + 1``.
.. _minio-ec-storage-class: .. _minio-ec-storage-class:
@ -225,6 +198,8 @@ MinIO provides the following two storage classes:
The maximum value is half of the total drives in the The maximum value is half of the total drives in the
:ref:`Erasure Set <minio-ec-erasure-set>`. :ref:`Erasure Set <minio-ec-erasure-set>`.
The minimum value is ``2``.
``STANDARD`` parity *must* be greater than or equal to ``STANDARD`` parity *must* be greater than or equal to
``REDUCED_REDUNDANCY``. If ``REDUCED_REDUNDANCY`` is unset, ``STANDARD`` ``REDUCED_REDUNDANCY``. If ``REDUCED_REDUNDANCY`` is unset, ``STANDARD``
parity *must* be greater than 2 parity *must* be greater than 2

Binary file not shown.

After

Width:  |  Height:  |  Size: 106 KiB

View File

@ -25,11 +25,14 @@ Standalone Deployments
to the full set of MinIO's advanced S3 features and functionality. to the full set of MinIO's advanced S3 features and functionality.
Distributed Deployments Distributed Deployments
Two or more MinIO servers with multiple storage volumes per server. One or more MinIO servers with *at least* four total storage volumes across
Distributed deployments are best for production environments and all servers. Distributed deployments are best for production environments and
workloads and support all of MinIO's core and advanced S3 features and workloads and support all of MinIO's core and advanced S3 features and
functionality. functionality.
MinIO recommends a baseline topology of 4 nodes with 4 drives each
for production environments.
.. _minio-installation-comparison: .. _minio-installation-comparison:
The following table compares the key functional differences between The following table compares the key functional differences between

View File

@ -43,7 +43,7 @@ Cluster Write Quorum
-------------------- --------------------
Use the following endpoint to test if a MinIO cluster has Use the following endpoint to test if a MinIO cluster has
:ref:`write quorum <minio-write-quorum>`: :ref:`write quorum <minio-ec-parity>`:
.. code-block:: shell .. code-block:: shell
:class: copyable :class: copyable
@ -76,7 +76,7 @@ Cluster Read Quorum
-------------------- --------------------
Use the following endpoint to test if a MinIO cluster has Use the following endpoint to test if a MinIO cluster has
:ref:`read quorum <minio-read-quorum>`: :ref:`read quorum <minio-ec-parity>`:
.. code-block:: shell .. code-block:: shell
:class: copyable :class: copyable
@ -104,7 +104,7 @@ Cluster Maintenance Check
------------------------- -------------------------
Use the following endpoint to test if the MinIO cluster can maintain Use the following endpoint to test if the MinIO cluster can maintain
both :ref:`read <minio-read-quorum>` and :ref:`write <minio-write-quorum>` both :ref:`read <minio-ec-parity>` and :ref:`write <minio-ec-parity>`
if the specified MinIO server is taken down for maintenance: if the specified MinIO server is taken down for maintenance:
.. code-block:: shell .. code-block:: shell