Corrected integer size passed to Windows
Corrected DisableEcho / SetRawTerminal to not modify state
Cleaned up and made routines more idiomatic
Corrected raw mode state bits
Removed duplicate IsTerminal
Corrected off-by-one error
Minor idiomatic change
Signed-off-by: Brendan Dixon <brendand@microsoft.com>
Updated Windows installation documentation with newest
screencasts and Chocolatey instructions to install windows
client CLI.
Signed-off-by: Ahmet Alp Balkan <ahmetalpbalkan@gmail.com>
registry/SearchResults was missing the "is_automated" field.
I added it back in.
Pull this 'table' removal one from the others because it fixed
a bug too
Signed-off-by: Doug Davis <dug@us.ibm.com>
* when no containers are returned, go test would then aborts with:
panic: runtime error: index out of range
Signed-off-by: Todd Whiteman <todd.whiteman@joyent.com>
Right now we try device removal at the interval of 10ms and keep on trying
till either device is removed or 10 seconds are over. That means if device
is busy, we will try 1000 times in those 10 seconds.
Sounds too high a frequency of deivce removal retrial. All the logs are
filled easily. I think it is a good idea to slow down a bit and retry at
the interval of 100ms instead of 10ms.
Signed-off-by: Vivek Goyal <vgoyal@redhat.com>
During device removal, we are first waiting for device to close() in a tight
loop for 10 seconds. I am not sure why do we need it. First of all we come
here once the umount() is successful so device should be free. For some reason
of device is temporarily busy, then removeDevice() logic retries device removal
logic in a loop for 10 seconds and that should cover it. Can't see why one
more 10 seoncds loop is required before attempting device removal.
One loop should be able to cover all the temporary device busy conditions and
if condition is not temporary then 10 seconds loop is not going to help anyway.
So instead of two loops of 10 seconds each, I am converting it to a single
loop of 20 seconds. May be 10 second loop is good enough but for now I am
keeping it 20 seconds to avoid any regressions.
Signed-off-by: Vivek Goyal <vgoyal@redhat.com>
Currently in device removal path (device deactivation), we wait
for 10 seconds for devive to actually go away. waitRemove().
In current code this is not required. If dm removal task has completed
and one has done the wait on udev cookie, then device is gone and there
is no need to write another loop to wait for device removal.
This patch removes the waitRemove() which waits for 10 seconds after
device removal. This seems unnecessary.
Signed-off-by: Vivek Goyal <vgoyal@redhat.com>