# Run this script to generated a faq.html output file
 | 
						|
#
 | 
						|
set rcsid {$Id: faq.tcl,v 1.40 2007/09/04 01:58:27 drh Exp $}
 | 
						|
source common.tcl
 | 
						|
header {SQLite Frequently Asked Questions</title>}
 | 
						|
 | 
						|
set cnt 1
 | 
						|
proc faq {question answer} {
 | 
						|
  set ::faq($::cnt) [list [string trim $question] [string trim $answer]]
 | 
						|
  incr ::cnt
 | 
						|
}
 | 
						|
 | 
						|
#############
 | 
						|
# Enter questions and answers here.
 | 
						|
 | 
						|
faq {
 | 
						|
  How do I create an AUTOINCREMENT field.
 | 
						|
} {
 | 
						|
  <p>Short answer: A column declared INTEGER PRIMARY KEY will
 | 
						|
  autoincrement.</p>
 | 
						|
 | 
						|
  <p>Here is the long answer:
 | 
						|
  If you declare a column of a table to be INTEGER PRIMARY KEY, then
 | 
						|
  whenever you insert a NULL
 | 
						|
  into that column of the table, the NULL is automatically converted
 | 
						|
  into an integer which is one greater than the largest value of that
 | 
						|
  column over all other rows in the table, or 1 if the table is empty.
 | 
						|
  (If the largest possible integer key, 9223372036854775807, then an
 | 
						|
  unused key value is chosen at random.)
 | 
						|
  For example, suppose you have a table like this:
 | 
						|
<blockquote><pre>
 | 
						|
CREATE TABLE t1(
 | 
						|
  a INTEGER PRIMARY KEY,
 | 
						|
  b INTEGER
 | 
						|
);
 | 
						|
</pre></blockquote>
 | 
						|
  <p>With this table, the statement</p>
 | 
						|
<blockquote><pre>
 | 
						|
INSERT INTO t1 VALUES(NULL,123);
 | 
						|
</pre></blockquote>
 | 
						|
  <p>is logically equivalent to saying:</p>
 | 
						|
<blockquote><pre>
 | 
						|
INSERT INTO t1 VALUES((SELECT max(a) FROM t1)+1,123);
 | 
						|
</pre></blockquote>
 | 
						|
 | 
						|
  <p>There is a new API function named
 | 
						|
  <a href="capi3ref.html#sqlite3_last_insert_rowid">
 | 
						|
  sqlite3_last_insert_rowid()</a> which will return the integer key
 | 
						|
  for the most recent insert operation.</p>
 | 
						|
 | 
						|
  <p>Note that the integer key is one greater than the largest
 | 
						|
  key that was in the table just prior to the insert.  The new key
 | 
						|
  will be unique over all keys currently in the table, but it might
 | 
						|
  overlap with keys that have been previously deleted from the
 | 
						|
  table.  To create keys that are unique over the lifetime of the
 | 
						|
  table, add the AUTOINCREMENT keyword to the INTEGER PRIMARY KEY
 | 
						|
  declaration.  Then the key chosen will be one more than than the
 | 
						|
  largest key that has ever existed in that table.  If the largest
 | 
						|
  possible key has previously existed in that table, then the INSERT
 | 
						|
  will fail with an SQLITE_FULL error code.</p>
 | 
						|
}
 | 
						|
 | 
						|
faq {
 | 
						|
  What datatypes does SQLite support?
 | 
						|
} {
 | 
						|
  <p>See <a href="datatype3.html">http://www.sqlite.org/datatype3.html</a>.</p>
 | 
						|
}
 | 
						|
 | 
						|
faq {
 | 
						|
  SQLite lets me insert a string into a database column of type integer!
 | 
						|
} {
 | 
						|
  <p>This is a feature, not a bug.  SQLite does not enforce data type
 | 
						|
  constraints.  Any data can be
 | 
						|
  inserted into any column.  You can put arbitrary length strings into
 | 
						|
  integer columns, floating point numbers in boolean columns, or dates
 | 
						|
  in character columns.  The datatype you assign to a column in the
 | 
						|
  CREATE TABLE command does not restrict what data can be put into
 | 
						|
  that column.  Every column is able to hold
 | 
						|
  an arbitrary length string.  (There is one exception: Columns of
 | 
						|
  type INTEGER PRIMARY KEY may only hold a 64-bit signed integer.
 | 
						|
  An error will result
 | 
						|
  if you try to put anything other than an integer into an
 | 
						|
  INTEGER PRIMARY KEY column.)</p>
 | 
						|
 | 
						|
  <p>But SQLite does use the declared type of a column as a hint
 | 
						|
  that you prefer values in that format.  So, for example, if a
 | 
						|
  column is of type INTEGER and you try to insert a string into
 | 
						|
  that column, SQLite will attempt to convert the string into an
 | 
						|
  integer.  If it can, it inserts the integer instead.  If not,
 | 
						|
  it inserts the string.  This feature is sometimes
 | 
						|
  call <a href="datatype3.html#affinity">type or column affinity</a>.
 | 
						|
  </p>
 | 
						|
}
 | 
						|
 | 
						|
faq {
 | 
						|
  Why doesn't SQLite allow me to use '0' and '0.0' as the primary
 | 
						|
  key on two different rows of the same table?
 | 
						|
} {
 | 
						|
  <p>Your primary key must have a numeric type.  Change the datatype of
 | 
						|
  your primary key to TEXT and it should work.</p>
 | 
						|
 | 
						|
  <p>Every row must have a unique primary key.  For a column with a
 | 
						|
  numeric type, SQLite thinks that <b>'0'</b> and <b>'0.0'</b> are the
 | 
						|
  same value because they compare equal to one another numerically.
 | 
						|
  (See the previous question.)  Hence the values are not unique.</p>
 | 
						|
}
 | 
						|
        
 | 
						|
 | 
						|
faq {
 | 
						|
  Can multiple applications or multiple instances of the same
 | 
						|
  application access a single database file at the same time?
 | 
						|
} {
 | 
						|
  <p>Multiple processes can have the same database open at the same
 | 
						|
  time.  Multiple processes can be doing a SELECT
 | 
						|
  at the same time.  But only one process can be making changes to
 | 
						|
  the database at any moment in time, however.</p>
 | 
						|
 | 
						|
  <p>SQLite uses reader/writer locks to control access to the database.
 | 
						|
  (Under Win95/98/ME which lacks support for reader/writer locks, a
 | 
						|
  probabilistic simulation is used instead.)
 | 
						|
  But use caution: this locking mechanism might
 | 
						|
  not work correctly if the database file is kept on an NFS filesystem.
 | 
						|
  This is because fcntl() file locking is broken on many NFS implementations.
 | 
						|
  You should avoid putting SQLite database files on NFS if multiple
 | 
						|
  processes might try to access the file at the same time.  On Windows,
 | 
						|
  Microsoft's documentation says that locking may not work under FAT
 | 
						|
  filesystems if you are not running the Share.exe daemon.  People who
 | 
						|
  have a lot of experience with Windows tell me that file locking of
 | 
						|
  network files is very buggy and is not dependable.  If what they
 | 
						|
  say is true, sharing an SQLite database between two or more Windows
 | 
						|
  machines might cause unexpected problems.</p>
 | 
						|
 | 
						|
  <p>We are aware of no other <i>embedded</i> SQL database engine that
 | 
						|
  supports as much concurrancy as SQLite.  SQLite allows multiple processes
 | 
						|
  to have the database file open at once, and for multiple processes to
 | 
						|
  read the database at once.  When any process wants to write, it must
 | 
						|
  lock the entire database file for the duration of its update.  But that
 | 
						|
  normally only takes a few milliseconds.  Other processes just wait on
 | 
						|
  the writer to finish then continue about their business.  Other embedded
 | 
						|
  SQL database engines typically only allow a single process to connect to
 | 
						|
  the database at once.</p>
 | 
						|
 | 
						|
  <p>However, client/server database engines (such as PostgreSQL, MySQL,
 | 
						|
  or Oracle) usually support a higher level of concurrency and allow
 | 
						|
  multiple processes to be writing to the same database at the same time.
 | 
						|
  This is possible in a client/server database because there is always a
 | 
						|
  single well-controlled server process available to coordinate access.
 | 
						|
  If your application has a need for a lot of concurrency, then you should
 | 
						|
  consider using a client/server database.  But experience suggests that
 | 
						|
  most applications need much less concurrency than their designers imagine.
 | 
						|
  </p>
 | 
						|
 | 
						|
  <p>When SQLite tries to access a file that is locked by another
 | 
						|
  process, the default behavior is to return SQLITE_BUSY.  You can
 | 
						|
  adjust this behavior from C code using the 
 | 
						|
  <a href="capi3ref.html#sqlite3_busy_handler">sqlite3_busy_handler()</a> or
 | 
						|
  <a href="capi3ref.html#sqlite3_busy_timeout">sqlite3_busy_timeout()</a>
 | 
						|
  API functions.</p>
 | 
						|
}
 | 
						|
 | 
						|
faq {
 | 
						|
  Is SQLite threadsafe?
 | 
						|
} {
 | 
						|
  <p>Yes.  Sometimes.  In order to be thread-safe, SQLite must be compiled
 | 
						|
  with the SQLITE_THREADSAFE preprocessor macro set to 1.  Both the windows
 | 
						|
  and linux precompiled binaries in the distribution are compiled this way.
 | 
						|
  If you are unsure if the SQLite library you are linking against is compiled
 | 
						|
  to be threadsafe you can call the
 | 
						|
  <a href="capi3ref.html#sqlite3_threadsafe">sqlite3_threadsafe()</a>
 | 
						|
  interface to find out.
 | 
						|
  </p>
 | 
						|
 | 
						|
  <p>Prior to version 3.3.1,
 | 
						|
  an <b>sqlite3</b> structure could only be used in the same thread
 | 
						|
  that called <a href="capi3ref.html#sqlite3_open">sqlite3_open</a>
 | 
						|
  to create it.
 | 
						|
  You could not open a
 | 
						|
  database in one thread then pass the handle off to another thread for
 | 
						|
  it to use.  This was due to limitations (bugs?) in many common threading
 | 
						|
  implementations such as on RedHat9.  Specifically, an fcntl() lock
 | 
						|
  created by one thread cannot be removed or modified by a different
 | 
						|
  thread on the troublesome systems.  And since SQLite uses fcntl()
 | 
						|
  locks heavily for concurrency control, serious problems arose if you 
 | 
						|
  start moving database connections across threads.</p>
 | 
						|
 | 
						|
  <p>The restriction on moving database connections across threads
 | 
						|
  was relaxed somewhat in version 3.3.1.  With that and subsequent
 | 
						|
  versions, it is safe to move a connection handle across threads
 | 
						|
  as long as the connection is not holding any fcntl() locks.  You
 | 
						|
  can safely assume that no locks are being held if no
 | 
						|
  transaction is pending and all statements have been finalized.</p>
 | 
						|
 | 
						|
  <p>Under UNIX, you should not carry an open SQLite database across
 | 
						|
  a fork() system call into the child process.  Problems will result
 | 
						|
  if you do.</p>
 | 
						|
}
 | 
						|
 | 
						|
faq {
 | 
						|
  How do I list all tables/indices contained in an SQLite database
 | 
						|
} {
 | 
						|
  <p>If you are running the <b>sqlite3</b> command-line access program
 | 
						|
  you can type "<b>.tables</b>" to get a list of all tables.  Or you
 | 
						|
  can type "<b>.schema</b>" to see the complete database schema including
 | 
						|
  all tables and indices.  Either of these commands can be followed by
 | 
						|
  a LIKE pattern that will restrict the tables that are displayed.</p>
 | 
						|
 | 
						|
  <p>From within a C/C++ program (or a script using Tcl/Ruby/Perl/Python
 | 
						|
  bindings) you can get access to table and index names by doing a SELECT
 | 
						|
  on a special table named "<b>SQLITE_MASTER</b>".  Every SQLite database
 | 
						|
  has an SQLITE_MASTER table that defines the schema for the database.
 | 
						|
  The SQLITE_MASTER table looks like this:</p>
 | 
						|
<blockquote><pre>
 | 
						|
CREATE TABLE sqlite_master (
 | 
						|
  type TEXT,
 | 
						|
  name TEXT,
 | 
						|
  tbl_name TEXT,
 | 
						|
  rootpage INTEGER,
 | 
						|
  sql TEXT
 | 
						|
);
 | 
						|
</pre></blockquote>
 | 
						|
  <p>For tables, the <b>type</b> field will always be <b>'table'</b> and the
 | 
						|
  <b>name</b> field will be the name of the table.  So to get a list of
 | 
						|
  all tables in the database, use the following SELECT command:</p>
 | 
						|
<blockquote><pre>
 | 
						|
SELECT name FROM sqlite_master
 | 
						|
WHERE type='table'
 | 
						|
ORDER BY name;
 | 
						|
</pre></blockquote>
 | 
						|
  <p>For indices, <b>type</b> is equal to <b>'index'</b>, <b>name</b> is the
 | 
						|
  name of the index and <b>tbl_name</b> is the name of the table to which
 | 
						|
  the index belongs.  For both tables and indices, the <b>sql</b> field is
 | 
						|
  the text of the original CREATE TABLE or CREATE INDEX statement that
 | 
						|
  created the table or index.  For automatically created indices (used
 | 
						|
  to implement the PRIMARY KEY or UNIQUE constraints) the <b>sql</b> field
 | 
						|
  is NULL.</p>
 | 
						|
 | 
						|
  <p>The SQLITE_MASTER table is read-only.  You cannot change this table
 | 
						|
  using UPDATE, INSERT, or DELETE.  The table is automatically updated by
 | 
						|
  CREATE TABLE, CREATE INDEX, DROP TABLE, and DROP INDEX commands.</p>
 | 
						|
 | 
						|
  <p>Temporary tables do not appear in the SQLITE_MASTER table.  Temporary
 | 
						|
  tables and their indices and triggers occur in another special table
 | 
						|
  named SQLITE_TEMP_MASTER.  SQLITE_TEMP_MASTER works just like SQLITE_MASTER
 | 
						|
  except that it is only visible to the application that created the 
 | 
						|
  temporary tables.  To get a list of all tables, both permanent and
 | 
						|
  temporary, one can use a command similar to the following:
 | 
						|
<blockquote><pre>
 | 
						|
SELECT name FROM 
 | 
						|
   (SELECT * FROM sqlite_master UNION ALL
 | 
						|
    SELECT * FROM sqlite_temp_master)
 | 
						|
WHERE type='table'
 | 
						|
ORDER BY name
 | 
						|
</pre></blockquote>
 | 
						|
}
 | 
						|
 | 
						|
faq {
 | 
						|
  Are there any known size limits to SQLite databases?
 | 
						|
} {
 | 
						|
  <p>See <a href="limits.html">limits.html</a> for a full discussion of
 | 
						|
  the limits of SQLite.</p>
 | 
						|
}
 | 
						|
 | 
						|
faq {
 | 
						|
  What is the maximum size of a VARCHAR in SQLite?
 | 
						|
} {
 | 
						|
  <p>SQLite does not enforce the length of a VARCHAR.  You can declare
 | 
						|
  a VARCHAR(10) and SQLite will be happy to let you put 500 characters
 | 
						|
  in it.  And it will keep all 500 characters intact - it never truncates.
 | 
						|
  </p>
 | 
						|
}
 | 
						|
 | 
						|
faq {
 | 
						|
  Does SQLite support a BLOB type?
 | 
						|
} {
 | 
						|
  <p>SQLite versions 3.0 and later allow you to store BLOB data in any 
 | 
						|
  column, even columns that are declared to hold some other type.</p>
 | 
						|
}
 | 
						|
 | 
						|
faq {
 | 
						|
  How do I add or delete columns from an existing table in SQLite.
 | 
						|
} {
 | 
						|
  <p>SQLite has limited 
 | 
						|
  <a href="lang_altertable.html">ALTER TABLE</a> support that you can
 | 
						|
  use to add a column to the end of a table or to change the name of
 | 
						|
  a table.  
 | 
						|
  If you what make more complex changes the structure of a table,
 | 
						|
  you will have to recreate the
 | 
						|
  table.  You can save existing data to a temporary table, drop the
 | 
						|
  old table, create the new table, then copy the data back in from
 | 
						|
  the temporary table.</p>
 | 
						|
 | 
						|
  <p>For example, suppose you have a table named "t1" with columns
 | 
						|
  names "a", "b", and "c" and that you want to delete column "c" from
 | 
						|
  this table.  The following steps illustrate how this could be done:
 | 
						|
  </p>
 | 
						|
 | 
						|
  <blockquote><pre>
 | 
						|
BEGIN TRANSACTION;
 | 
						|
CREATE TEMPORARY TABLE t1_backup(a,b);
 | 
						|
INSERT INTO t1_backup SELECT a,b FROM t1;
 | 
						|
DROP TABLE t1;
 | 
						|
CREATE TABLE t1(a,b);
 | 
						|
INSERT INTO t1 SELECT a,b FROM t1_backup;
 | 
						|
DROP TABLE t1_backup;
 | 
						|
COMMIT;
 | 
						|
</pre></blockquote>
 | 
						|
}
 | 
						|
 | 
						|
faq {
 | 
						|
  I deleted a lot of data but the database file did not get any
 | 
						|
  smaller.  Is this a bug?
 | 
						|
} {
 | 
						|
  <p>No.  When you delete information from an SQLite database, the
 | 
						|
  unused disk space is added to an internal "free-list" and is reused
 | 
						|
  the next time you insert data.  The disk space is not lost.  But
 | 
						|
  neither is it returned to the operating system.</p>
 | 
						|
 | 
						|
  <p>If you delete a lot of data and want to shrink the database file,
 | 
						|
  run the <a href="lang_vacuum.html">VACUUM</a> command.
 | 
						|
  VACUUM will reconstruct
 | 
						|
  the database from scratch.  This will leave the database with an empty
 | 
						|
  free-list and a file that is minimal in size.  Note, however, that the
 | 
						|
  VACUUM can take some time to run (around a half second per megabyte
 | 
						|
  on the Linux box where SQLite is developed) and it can use up to twice
 | 
						|
  as much temporary disk space as the original file while it is running.
 | 
						|
  </p>
 | 
						|
 | 
						|
  <p>As of SQLite version 3.1, an alternative to using the VACUUM command
 | 
						|
  is auto-vacuum mode, enabled using the 
 | 
						|
  <a href="pragma.html#pragma_auto_vacuum">auto_vacuum pragma</a>.</p>
 | 
						|
}
 | 
						|
 | 
						|
faq {
 | 
						|
  Can I use SQLite in my commercial product without paying royalties?
 | 
						|
} {
 | 
						|
  <p>Yes.  SQLite is in the 
 | 
						|
  <a href="copyright.html">public domain</a>.  No claim of ownership is made
 | 
						|
  to any part of the code.  You can do anything you want with it.</p>
 | 
						|
}
 | 
						|
 | 
						|
faq {
 | 
						|
  How do I use a string literal that contains an embedded single-quote (')
 | 
						|
  character?
 | 
						|
} {
 | 
						|
  <p>The SQL standard specifies that single-quotes in strings are escaped
 | 
						|
  by putting two single quotes in a row.  SQL works like the Pascal programming
 | 
						|
  language in the regard.  SQLite follows this standard.  Example:
 | 
						|
  </p>
 | 
						|
 | 
						|
  <blockquote><pre>
 | 
						|
    INSERT INTO xyz VALUES('5 O''clock');
 | 
						|
  </pre></blockquote>
 | 
						|
}
 | 
						|
 | 
						|
faq {What is an SQLITE_SCHEMA error, and why am I getting one?} {
 | 
						|
  <p>An SQLITE_SCHEMA error is returned when a 
 | 
						|
  prepared SQL statement is no longer valid and cannot be executed.
 | 
						|
  When this occurs, the statement must be recompiled from SQL using 
 | 
						|
  the 
 | 
						|
  <a href="capi3ref.html#sqlite3_prepare">sqlite3_prepare()</a> API.
 | 
						|
  In SQLite version 3, an SQLITE_SCHEMA error can
 | 
						|
  only occur when using the 
 | 
						|
  <a href="capi3ref.html#sqlite3_prepare">sqlite3_prepare()</a>/<a
 | 
						|
  href="capi3ref.html#sqlite3_step">sqlite3_step()</a>/<a
 | 
						|
  href="capi3ref.html#sqlite3_finalize">sqlite3_finalize()</a>
 | 
						|
  API to execute SQL, not when using the
 | 
						|
  <a href="capi3ref.html#sqlite3_exec">sqlite3_exec()</a>. This was not
 | 
						|
  the case in version 2.</p>
 | 
						|
 | 
						|
  <p>The most common reason for a prepared statement to become invalid
 | 
						|
  is that the schema of the database was modified after the SQL was 
 | 
						|
  prepared (possibly by another process).  The other reasons this can 
 | 
						|
  happen are:</p> 
 | 
						|
  <ul>
 | 
						|
  <li>A database was <a href="lang_detach.html">DETACH</a>ed.
 | 
						|
  <li>The database was <a href="lang_vacuum.html">VACUUM</a>ed
 | 
						|
  <li>A user-function definition was deleted or changed.
 | 
						|
  <li>A collation sequence definition was deleted or changed.
 | 
						|
  <li>The authorization function was changed.
 | 
						|
  </ul>
 | 
						|
 | 
						|
  <p>In all cases, the solution is to recompile the statement from SQL
 | 
						|
  and attempt to execute it again. Because a prepared statement can be
 | 
						|
  invalidated by another process changing the database schema, all code
 | 
						|
  that uses the
 | 
						|
  <a href="capi3ref.html#sqlite3_prepare">sqlite3_prepare()</a>/<a
 | 
						|
  href="capi3ref.html#sqlite3_step">sqlite3_step()</a>/<a
 | 
						|
  href="capi3ref.html#sqlite3_finalize">sqlite3_finalize()</a>
 | 
						|
  API should be prepared to handle SQLITE_SCHEMA errors. An example
 | 
						|
  of one approach to this follows:</p>
 | 
						|
 | 
						|
  <blockquote><pre>
 | 
						|
 | 
						|
    int rc;
 | 
						|
    sqlite3_stmt *pStmt;
 | 
						|
    char zSql[] = "SELECT .....";
 | 
						|
 | 
						|
    do {
 | 
						|
      /* Compile the statement from SQL. Assume success. */
 | 
						|
      sqlite3_prepare(pDb, zSql, -1, &pStmt, 0);
 | 
						|
 | 
						|
      while( SQLITE_ROW==sqlite3_step(pStmt) ){
 | 
						|
        /* Do something with the row of available data */
 | 
						|
      }
 | 
						|
 | 
						|
      /* Finalize the statement. If an SQLITE_SCHEMA error has
 | 
						|
      ** occured, then the above call to sqlite3_step() will have
 | 
						|
      ** returned SQLITE_ERROR. sqlite3_finalize() will return
 | 
						|
      ** SQLITE_SCHEMA. In this case the loop will execute again.
 | 
						|
      */
 | 
						|
      rc = sqlite3_finalize(pStmt);
 | 
						|
    } while( rc==SQLITE_SCHEMA );
 | 
						|
    
 | 
						|
  </pre></blockquote>
 | 
						|
}
 | 
						|
 | 
						|
faq {Why does ROUND(9.95,1)  return 9.9 instead of 10.0?
 | 
						|
     Shouldn't 9.95 round up?} {
 | 
						|
  <p>SQLite uses binary arithmetic and in binary, there is no
 | 
						|
  way to write 9.95 in a finite number of bits.  The closest to
 | 
						|
  you can get to 9.95 in a 64-bit IEEE float (which is what
 | 
						|
  SQLite uses) is 9.949999999999999289457264239899814128875732421875.
 | 
						|
  So when you type "9.95", SQLite really understands the number to be
 | 
						|
  the much longer value shown above.  And that value rounds down.</p>
 | 
						|
 | 
						|
  <p>This kind of problem comes up all the time when dealing with
 | 
						|
  floating point binary numbers.  The general rule to remember is
 | 
						|
  that most fractional numbers that have a finite representation in decimal
 | 
						|
  (a.k.a "base-10")
 | 
						|
  do not have a finite representation in binary (a.k.a "base-2").
 | 
						|
  And so they are
 | 
						|
  approximated using the closest binary number available.  That
 | 
						|
  approximation is usually very close, but it will be slightly off
 | 
						|
  and in some cases can cause your results to be a little different
 | 
						|
  from what you might expect.</p>
 | 
						|
}
 | 
						|
 | 
						|
# End of questions and answers.
 | 
						|
#############
 | 
						|
 | 
						|
puts {<h2>Frequently Asked Questions</h2>}
 | 
						|
 | 
						|
# puts {<DL COMPACT>}
 | 
						|
# for {set i 1} {$i<$cnt} {incr i} {
 | 
						|
#   puts "  <DT><A HREF=\"#q$i\">($i)</A></DT>"
 | 
						|
#   puts "  <DD>[lindex $faq($i) 0]</DD>"
 | 
						|
# }
 | 
						|
# puts {</DL>}
 | 
						|
puts {<OL>}
 | 
						|
for {set i 1} {$i<$cnt} {incr i} {
 | 
						|
  puts "<li><a href=\"#q$i\">[lindex $faq($i) 0]</a></li>"
 | 
						|
}
 | 
						|
puts {</OL>}
 | 
						|
 | 
						|
for {set i 1} {$i<$cnt} {incr i} {
 | 
						|
  puts "<A NAME=\"q$i\"><HR />"
 | 
						|
  puts "<P><B>($i) [lindex $faq($i) 0]</B></P>\n"
 | 
						|
  puts "<BLOCKQUOTE>[lindex $faq($i) 1]</BLOCKQUOTE></LI>\n"
 | 
						|
}
 | 
						|
 | 
						|
puts {</OL>}
 | 
						|
footer $rcsid
 |