1
0
mirror of https://github.com/sqlite/sqlite.git synced 2025-11-12 13:01:09 +03:00

Merge latest trunk changes with this branch.

FossilOrigin-Name: 251022034219819a1dc356542770ff46e3147a080f072eb20af6106771dadd92
This commit is contained in:
dan
2018-06-07 20:35:28 +00:00
28 changed files with 381 additions and 171 deletions

View File

@@ -5104,11 +5104,17 @@ static void finalizeAggFunctions(Parse *pParse, AggInfo *pAggInfo){
}
}
/*
** Update the accumulator memory cells for an aggregate based on
** the current cursor position.
**
** If regAcc is non-zero and there are no min() or max() aggregates
** in pAggInfo, then only populate the pAggInfo->nAccumulator accumulator
** registers i register regAcc contains 0. The caller will take care
** of setting and clearing regAcc.
*/
static void updateAccumulator(Parse *pParse, AggInfo *pAggInfo){
static void updateAccumulator(Parse *pParse, int regAcc, AggInfo *pAggInfo){
Vdbe *v = pParse->pVdbe;
int i;
int regHit = 0;
@@ -5172,6 +5178,9 @@ static void updateAccumulator(Parse *pParse, AggInfo *pAggInfo){
** Another solution would be to change the OP_SCopy used to copy cached
** values to an OP_Copy.
*/
if( regHit==0 && pAggInfo->nAccumulator ){
regHit = regAcc;
}
if( regHit ){
addrHitTest = sqlite3VdbeAddOp1(v, OP_If, regHit); VdbeCoverage(v);
}
@@ -6067,8 +6076,6 @@ int sqlite3Select(
pParse->nMem += pGroupBy->nExpr;
sqlite3VdbeAddOp2(v, OP_Integer, 0, iAbortFlag);
VdbeComment((v, "clear abort flag"));
sqlite3VdbeAddOp2(v, OP_Integer, 0, iUseFlag);
VdbeComment((v, "indicate accumulator empty"));
sqlite3VdbeAddOp3(v, OP_Null, 0, iAMem, iAMem+pGroupBy->nExpr-1);
/* Begin a loop that will extract all source rows in GROUP BY order.
@@ -6201,7 +6208,7 @@ int sqlite3Select(
** the current row
*/
sqlite3VdbeJumpHere(v, addr1);
updateAccumulator(pParse, &sAggInfo);
updateAccumulator(pParse, iUseFlag, &sAggInfo);
sqlite3VdbeAddOp2(v, OP_Integer, 1, iUseFlag);
VdbeComment((v, "indicate data in accumulator"));
@@ -6253,6 +6260,8 @@ int sqlite3Select(
*/
sqlite3VdbeResolveLabel(v, addrReset);
resetAccumulator(pParse, &sAggInfo);
sqlite3VdbeAddOp2(v, OP_Integer, 0, iUseFlag);
VdbeComment((v, "indicate accumulator empty"));
sqlite3VdbeAddOp1(v, OP_Return, regReset);
} /* endif pGroupBy. Begin aggregate queries without GROUP BY: */
@@ -6318,6 +6327,23 @@ int sqlite3Select(
}else
#endif /* SQLITE_OMIT_BTREECOUNT */
{
int regAcc = 0; /* "populate accumulators" flag */
/* If there are accumulator registers but no min() or max() functions,
** allocate register regAcc. Register regAcc will contain 0 the first
** time the inner loop runs, and 1 thereafter. The code generated
** by updateAccumulator() only updates the accumulator registers if
** regAcc contains 0. */
if( sAggInfo.nAccumulator ){
for(i=0; i<sAggInfo.nFunc; i++){
if( sAggInfo.aFunc[i].pFunc->funcFlags&SQLITE_FUNC_NEEDCOLL ) break;
}
if( i==sAggInfo.nFunc ){
regAcc = ++pParse->nMem;
sqlite3VdbeAddOp2(v, OP_Integer, 0, regAcc);
}
}
/* This case runs if the aggregate has no GROUP BY clause. The
** processing is much simpler since there is only a single row
** of output.
@@ -6339,7 +6365,8 @@ int sqlite3Select(
if( pWInfo==0 ){
goto select_end;
}
updateAccumulator(pParse, &sAggInfo);
updateAccumulator(pParse, regAcc, &sAggInfo);
if( regAcc ) sqlite3VdbeAddOp2(v, OP_Integer, 1, regAcc);
if( sqlite3WhereIsOrdered(pWInfo)>0 ){
sqlite3VdbeGoto(v, sqlite3WhereBreakLabel(pWInfo));
VdbeComment((v, "%s() by index",