Frequently Asked Questions (FAQ) for PostgreSQL
 | 
						|
HP-UX Specific
 | 
						|
TO BE READ IN CONJUNCTION WITH THE NORMAL FAQ
 | 
						|
=======================================================
 | 
						|
last updated:           $Date: 2006/12/06 15:45:30 $
 | 
						|
 | 
						|
current maintainer:     Tom Lane (tgl@sss.pgh.pa.us)
 | 
						|
original author:        Tom Lane (tgl@sss.pgh.pa.us)
 | 
						|
 | 
						|
 | 
						|
Questions covered here:
 | 
						|
1.1)	What do I need to install PostgreSQL on HP-UX?
 | 
						|
1.2)	Anything special about the build/install procedure?
 | 
						|
1.3)	OK, it seemed to build and install, but the regression test fails.
 | 
						|
 | 
						|
 | 
						|
----------------------------------------------------------------------
 | 
						|
Section 1:      Installing PostgreSQL
 | 
						|
----------------------------------------------------------------------
 | 
						|
 | 
						|
1.1)	What do I need to install PostgreSQL on HP-UX?
 | 
						|
 | 
						|
PostgreSQL 7.3+ should work on Series 700/800 PA-RISC machines running
 | 
						|
HP-UX 10.X or 11.X, given appropriate system patch levels and build
 | 
						|
tools.  At least one developer routinely tests on HPUX 10.20 and we
 | 
						|
have reports of successful installations on HPUX 11.00 and 11.11.
 | 
						|
 | 
						|
Aside from the PostgreSQL source distribution, you will need GNU make
 | 
						|
(HP's make will not do), and either GNU gcc or HP's full ANSI C compiler.
 | 
						|
If you intend to build from CVS sources rather than a distribution tarball,
 | 
						|
you will also need flex (GNU lex) and bison (GNU yacc).
 | 
						|
 | 
						|
I'd also recommend making sure you are fairly up-to-date on HP
 | 
						|
patches.  At a minimum, if you are building 64 bit binaries on on HPUX
 | 
						|
11.11 you may need PHSS_30966 (11.11) or a successor patch otherwise
 | 
						|
initdb may hang:
 | 
						|
 | 
						|
    PHSS_30966  s700_800 ld(1) and linker tools cumulative patch
 | 
						|
 | 
						|
On general principles you should be current on libc and ld/dld
 | 
						|
patches, as well as compiler patches if you are using HP's C compiler.
 | 
						|
See HP's support sites such as http://itrc.hp.com and
 | 
						|
ftp://us-ffs.external.hp.com/ for free copies of their latest patches.
 | 
						|
 | 
						|
If you are building on a PA-RISC 2.0 machine and want to have 64-bit
 | 
						|
binaries using GCC, you must use GCC 64-bit version. GCC binaries for
 | 
						|
HP-UX PA-RISC and Itanium are available from http://www.hp.com/go/gcc.
 | 
						|
Don't forget to get and install binutils at the same time.
 | 
						|
 | 
						|
If you are building on a HP-UX Itanium machine, you will need the
 | 
						|
latest HP ANSI C compiler with its dependent patch or successor
 | 
						|
patches:
 | 
						|
 | 
						|
    PHSS_30848  s700_800 HP C Compiler (A.05.57)
 | 
						|
    PHSS_30849  s700_800 u2comp/be/plugin library Patch
 | 
						|
 | 
						|
1.2)	Anything special about the build/install procedure?
 | 
						|
 | 
						|
If you have both HP's C compiler and GCC's, then you might want to
 | 
						|
explicitly select the compiler to use when you run `configure':
 | 
						|
	./configure CC=cc
 | 
						|
for HP's C compiler, or
 | 
						|
	./configure CC=gcc
 | 
						|
for GCC.  If you omit this setting, then configure will pick gcc
 | 
						|
if it has a choice.
 | 
						|
 | 
						|
The default install target location is /usr/local/pgsql, which
 | 
						|
you might want to change to something under /opt.  If so, use
 | 
						|
the --prefix switch to configure.
 | 
						|
 | 
						|
If you are building on a PA-RISC 2.0 machine and want the compiled
 | 
						|
binaries to run on PA-RISC 1.1 machines you will need to specify
 | 
						|
+DAportable in CFLAGS.
 | 
						|
 | 
						|
 | 
						|
1.3)	OK, it seemed to build and install, but the regression test fails.
 | 
						|
 | 
						|
There are several "expected failures" due to differences between HPUX
 | 
						|
and the regression test reference platform used by the PostgreSQL
 | 
						|
group.  All of these should be compensated for by the regression test
 | 
						|
comparison mechanism, with the possible exception of some
 | 
						|
low-order-digit differences in the geometry tests, which vary depending
 | 
						|
on which compiler and math library versions you use.
 | 
						|
 | 
						|
Any other error is cause for suspicion.
 |