1
0
mirror of https://github.com/MariaDB/server.git synced 2025-07-04 01:23:45 +03:00
Files
mariadb/mysql-test/suite/binlog/r/binlog_spurious_ddl_errors.result
Astha Pareek 9b904d35af Description
The test, binlog.binlog_spurious_ddl_errors was failing on pb2 at the statement
      "UNINSTALL PLUGIN example;" with this warning:
      "Warning	1620	Plugin is busy and will be uninstalled on shutdown "
      
      Fix
      Spurious warnings occur in the test since we do not empty the Query cache,
      used by the example plugin at the time of creating tables using the plugin.
      Hence, the query chache is flushed before uninstalling the plugin.
      Also, as part of running the test across platforms, the plugin installation
      script is changed.
2013-01-18 12:32:37 +05:30

55 lines
3.0 KiB
Plaintext

SET @old_binlog_format= @@global.binlog_format;
INSTALL PLUGIN example SONAME 'ha_example.so';
################################################################################
# Verifies if ER_BINLOG_STMT_MODE_AND_ROW_ENGINE happens by setting the binlog
# format to STATEMENT and the transaction isolation level to READ COMMITTED as
# such changes force Innodb to accept changes in the row format.
#
# When CREATE TABLE, ALTER TABLE, CREATE INDEX and CREATE TRIGGER are executed
# any error should be triggered.
#
# In contrast, CREATE TABLE ... SELECT should trigger the following error:
# ER_BINLOG_STMT_MODE_AND_ROW_ENGINE.
################################################################################
SET binlog_format = STATEMENT;
SET SESSION TRANSACTION ISOLATION LEVEL READ COMMITTED;
CREATE TABLE t_row (a VARCHAR(100)) ENGINE = InnoDB;
ALTER TABLE t_row ADD COLUMN b INT;
CREATE TRIGGER trig_row BEFORE INSERT ON t_row FOR EACH ROW INSERT INTO t_stmt VALUES (1);
CREATE INDEX i ON t_row(a);
CREATE TABLE t_row_new ENGINE = InnoDB SELECT * FROM t_row;
ERROR HY000: Cannot execute statement: impossible to write to binary log since BINLOG_FORMAT = STATEMENT and at least one table uses a storage engine limited to row-based logging. InnoDB is limited to row-logging when transaction isolation level is READ COMMITTED or READ UNCOMMITTED.
DROP TABLE t_row;
################################################################################
# Verifies if ER_BINLOG_ROW_MODE_AND_STMT_ENGINE happens by setting the binlog
# format to ROW and using a engine, i.e. EXAMPLE, that only supports STATEMENT.
#
# When CREATE TABLE, ALTER TABLE, CREATE INDEX and CREATE TRIGGER are executed
# the error ER_BINLOG_ROW_MODE_AND_STMT_ENGINE is not triggered. Note that other
# errors are triggered due to restrictions in the engine.
#
# In contrast, CREATE TABLE ... SELECT should trigger the following error:
# ER_BINLOG_ROW_MODE_AND_STMT_ENGINE.
################################################################################
SET binlog_format = ROW;
CREATE TABLE t_stmt (a VARCHAR(100)) ENGINE = EXAMPLE;
ALTER TABLE t_stmt ADD COLUMN b INT;
ERROR 42000: This version of MySQL doesn't yet support 'ALTER TABLE'
CREATE TRIGGER trig_stmt BEFORE INSERT ON t_stmt FOR EACH ROW INSERT INTO t_stmt VALUES (1);
CREATE INDEX i ON t_stmt(a);
ERROR 42000: Too many key parts specified; max 0 parts allowed
CREATE TABLE t_stmt_new ENGINE = EXAMPLE SELECT * FROM t_stmt;
ERROR HY000: Cannot execute statement: impossible to write to binary log since BINLOG_FORMAT = ROW and at least one table uses a storage engine limited to statement-based logging.
DROP TABLE t_stmt;
################################################################################
# CLEAN UP #
################################################################################
flush tables;
UNINSTALL PLUGIN example;
SET @@global.binlog_format = @old_binlog_format;