1
0
mirror of https://github.com/MariaDB/server.git synced 2025-08-09 22:24:09 +03:00
Files
mariadb/mysql-test/suite/rpl/t/rpl_stm_user_variables.test
Luis Soares 229da7c0dd BUG#51426: overflow for auto_increment column causes slave to stop
In BUG#49562 we fixed the case where numeric user var events
would not serialize the flag stating whether the value was signed
or unsigned (unsigned_flag). This fixed the case that the slave
would get an overflow while treating the unsigned values as
signed.
      
In this bug, we find that the unsigned_flag can sometimes change
between the moment that the user value is recorded for binlogging
purposes and the actual binlogging time. Since we take the
unsigned_flag from the runtime variable data, at binlogging time,
and the variable value is comes from the copy taken earlier in
the execution, there may be inconsistency in the
User_var_log_event between the variable value and its
unsigned_flag.
      
We fix this by also copying the unsigned_flag of the
user_var_entry when its value is copied, for binlogging
purposes. Later, at binlogging time, we use the copied
unsigned_flag and not the one in the runtime user_var_entry
instance.
2010-03-17 00:06:13 +00:00

175 lines
5.5 KiB
Plaintext

#
# BUG#49562: SBR out of sync when using numeric data types + user variable
#
-- source include/master-slave.inc
-- source include/have_binlog_format_statement.inc
## Setup user variables for several numeric types, so that we get
## coverage on the User_var_log_event different val types
-- let $max_unsigned_long= 18446744073709551615
-- let $min_signed_long= -9223372036854775808
-- eval SET @positive= $max_unsigned_long
-- eval SET @negative= $min_signed_long
CREATE TABLE t1 (`tinyint` TINYINT,
`smallint` SMALLINT,
`mediumint` MEDIUMINT,
`integer` INTEGER,
`bigint` BIGINT,
`utinyint` TINYINT UNSIGNED,
`usmallint` SMALLINT UNSIGNED,
`umediumint` MEDIUMINT UNSIGNED,
`uinteger` INTEGER UNSIGNED,
`ubigint` BIGINT UNSIGNED,
`double` DOUBLE,
`float` FLOAT,
`real` REAL(30,2),
`decimal` DECIMAL(30,2)) ENGINE = MyISAM;
-- disable_warnings
-- echo ### insert max unsigned
-- echo ### a) declarative
-- eval INSERT INTO t1 VALUES ($max_unsigned_long, $max_unsigned_long, $max_unsigned_long, $max_unsigned_long, $max_unsigned_long, $max_unsigned_long, $max_unsigned_long,$max_unsigned_long, $max_unsigned_long, $max_unsigned_long, $max_unsigned_long, $max_unsigned_long, $max_unsigned_long, $max_unsigned_long);
-- echo #########################################
-- echo #### [ on master ]
-- query_vertical SELECT * FROM t1
-- sync_slave_with_master
-- echo #### [ on slave ]
-- query_vertical SELECT * FROM t1
-- echo #########################################
-- connection master
-- echo ## assertion: master and slave tables are in sync
-- let $diff_table_1=master:test.t1
-- let $diff_table_2=slave:test.t1
-- source include/diff_tables.inc
-- connection master
TRUNCATE t1;
-- echo ### b) user var
INSERT INTO t1 VALUES (@positive,
@positive,
@positive,
@positive,
@positive,
@positive,
@positive,
@positive,
@positive,
@positive,
@positive,
@positive,
@positive,
@positive);
-- echo #########################################
-- echo #### [ on master ]
-- query_vertical SELECT * FROM t1
-- sync_slave_with_master
-- echo #### [ on slave ]
-- query_vertical SELECT * FROM t1
-- echo #########################################
-- connection master
-- echo ## assertion: master and slave tables are in sync
-- let $diff_table_1=master:test.t1
-- let $diff_table_2=slave:test.t1
-- source include/diff_tables.inc
-- connection master
TRUNCATE t1;
-- echo ### insert min signed
-- echo ### a) declarative
-- eval INSERT INTO t1 VALUES ($min_signed_long, $min_signed_long, $min_signed_long, $min_signed_long, $min_signed_long, $min_signed_long, $min_signed_long,$min_signed_long, $min_signed_long, $min_signed_long, $min_signed_long, $min_signed_long, $min_signed_long, $min_signed_long);
-- echo #########################################
-- echo #### [ on master ]
-- query_vertical SELECT * FROM t1
-- sync_slave_with_master
-- echo #### [ on slave ]
-- query_vertical SELECT * FROM t1
-- echo #########################################
-- connection master
-- echo ## assertion: master and slave tables are in sync
-- let $diff_table_1=master:test.t1
-- let $diff_table_2=slave:test.t1
-- source include/diff_tables.inc
-- connection master
TRUNCATE t1;
-- echo ### b) user var
INSERT INTO t1 VALUES (@negative,
@negative,
@negative,
@negative,
@negative,
@negative,
@negative,
@negative,
@negative,
@negative,
@negative,
@negative,
@negative,
@negative);
-- echo #########################################
-- echo #### [ on master ]
-- query_vertical SELECT * FROM t1
-- sync_slave_with_master
-- echo #### [ on slave ]
-- query_vertical SELECT * FROM t1
-- echo #########################################
-- connection master
-- echo ## assertion: master and slave tables are in sync
-- let $diff_table_1=master:test.t1
-- let $diff_table_2=slave:test.t1
-- source include/diff_tables.inc
-- connection master
TRUNCATE t1;
-- echo ## check: contents of both tables master's and slave's
-- enable_warnings
## cleanup
-- connection master
DROP TABLE t1;
-- sync_slave_with_master
#####################################################################
#
# BUG#51426
#
#####################################################################
-- source include/master-slave-reset.inc
-- connection master
CREATE TABLE t1 ( c INT, PRIMARY KEY (c)) Engine=MyISAM;
# offending trigger that would reset the unsigned flag for aux before
# binlogging of User_var_log_event would take place.
CREATE TRIGGER tr1 AFTER INSERT ON t1 FOR EACH ROW SET @aux = -1 ;
SET @aux = 10294947273192243200;
SET @aux1= @aux;
-- error ER_DUP_ENTRY
INSERT INTO t1 VALUES (@aux) , (@aux1);
-- sync_slave_with_master
-- echo ## assertion: master and slave tables are in sync
-- let $diff_table_1=master:test.t1
-- let $diff_table_2=slave:test.t1
-- source include/diff_tables.inc
--connection master
DROP TRIGGER tr1;
DROP TABLE t1;
-- sync_slave_with_master