1. BUG#46000 - using index called GEN_CLUST_INDEX crashes server
Detailed revision comments:
r5895 | jyang | 2009-09-15 03:39:21 +0300 (Tue, 15 Sep 2009) | 5 lines
branches/5.1: Disallow creating index with the name of
"GEN_CLUST_INDEX" which is reserved for the default system
primary index. (Bug #46000) rb://149 approved by Marko Makela.
The problem is that safe_kill_win fails to detect a dead process. OpenProcess() will
succeed even after the process died, it will first fail after the last handle to process
is closed.
To fix the problem, check process status with GetExitCodeProcess() and consider
process to be dead if the exit code returned by this routine is not STILL_ALIVE.
value from the index (PRIMARY)
With the fix for BUG#46760, we correctly flag the presence of row_type
only when it's actually changed and enables the FAST ALTER TABLE which was
disabled with the BUG#39200.
So the changes made by BUG#46760 makes MySQL data dictionaries to be out of
sync but they are handled already by InnoDB with this BUG#44030.
The test was originally written to handle this but we requested Innodb to
update the test as the data dictionaries were in sync after the fix for
BUG#39200.
Adjusting the innodb-autoinc testcase as mentioned in the comments.
1. Fixes BUG#44030 - Error: (1500) Couldn't read the MAX(ID) autoinc value
from the index (PRIMARY)
2. Disables the innodb-autoinc test for innodb plugin temporarily.
The testcase for this bug has different result file for InnoDB plugin.
Should add the testcase to Innodb suite with a different result file.
Detailed revision comments:
r5243 | sunny | 2009-06-04 03:17:14 +0300 (Thu, 04 Jun 2009) | 14 lines
branches/5.1: When the InnoDB and MySQL data dictionaries go out of sync, before
the bug fix we would assert on missing autoinc columns. With this fix we allow
MySQL to open the table but set the next autoinc value for the column to the
MAX value. This effectively disables the next value generation. INSERTs will
fail with a generic AUTOINC failure. However, the user should be able to
read/dump the table, set the column values explicitly, use ALTER TABLE to
set the next autoinc value and/or sync the two data dictionaries to resume
normal operations.
Fix Bug#44030 Error: (1500) Couldn't read the MAX(ID) autoinc value from the
index (PRIMARY)
rb://118
r5252 | sunny | 2009-06-04 10:16:24 +0300 (Thu, 04 Jun 2009) | 2 lines
branches/5.1: The version of the result file checked in was broken in r5243.
r5259 | vasil | 2009-06-05 10:29:16 +0300 (Fri, 05 Jun 2009) | 7 lines
branches/5.1:
Remove the word "Error" from the printout because the mysqltest suite
interprets it as an error and thus the innodb-autoinc test fails.
Approved by: Sunny (via IM)
r5466 | vasil | 2009-07-02 10:46:45 +0300 (Thu, 02 Jul 2009) | 6 lines
branches/5.1:
Adjust the failing innodb-autoinc test to conform to the latest behavior
of the MySQL code. The idea and the comment in innodb-autoinc.test come
from Sunny.
Bug in Perl
Scrap attempt to do this smartly on AIX, just drop the test and assume it's OK
This commit undoes the previous push and adds a line to ignore on AIX
Suspected reason for the failure is that safe_process.exe already runs in a job that does not allow breakaways.
The fix is to use a fallback - make newly created process the root of the new process group. This allows to kill process together with descendants via GenerateConsoleCtrlEvent (CTRL_BREAK_EVENT, pid)
It is not possible to prevent the server from starting if a mandatory
built-in plugin fails to start. This can in some cases lead to data
corruption when the old table name space suddenly is used by a different
storage engine.
A boolean command line option in the form of --foobar is automatically
created for every existing plugin "foobar". By changing this command line
option from a boolean to a tristate { OFF, ON, FORCE } it is possible to
specify the plugin loading policy for each plugin.
The behavior is specified as follows:
OFF = Disable the plugin and start the server
ON = Enable the plugin and start the server even if an error occurrs
during plugin initialization.
FORCE = Enable the plugin but don't start the server if an error occurrs
during plugin initialization.
MTR is stuck for about 20 seconds checking for free ports.
The reason is that perl's connect() takes 1 second on windows
if port is not opened.
This patch fixes the mtr_ping_port implementation on Windows
to use Net::Ping for the port checking with small (0.1sec) timeout.
This patch also removes pointless second call to check_ports_free()
in case of auto build thread.