This allows one to run the test suite even if any of the following
options are changed:
- character-set-server
- collation-server
- join-cache-level
- log-basename
- max-allowed-packet
- optimizer-switch
- query-cache-size and query-cache-type
- skip-name-resolve
- table-definition-cache
- table-open-cache
- Some innodb options
etc
Changes:
- Don't print out the value of system variables as one can't depend on
them to being constants.
- Don't set global variables to 'default' as the default may not
be the same as the test was started with if there was an additional
option file. Instead save original value and reset it at end of test.
- Test that depends on the latin1 character set should include
default_charset.inc or set the character set to latin1
- Test that depends on the original optimizer switch, should include
default_optimizer_switch.inc
- Test that depends on the value of a specific system variable should
set it in the test (like optimizer_use_condition_selectivity)
- Split subselect3.test into subselect3.test and subselect3.inc to
make it easier to set and reset system variables.
- Added .opt files for test that required specfic options that could
be changed by external configuration files.
- Fixed result files in rockdsb & tokudb that had not been updated for
a while.
new features:
set event_scheduler=ON|OFF will now try to init event scheduler
if it's not enabled
set event_scheduler=default will try to enable it based on
the value of the event_scheduler when mysqld was started
Problem: Statements that write to tables with auto_increment columns
based on the selection from another table, may lead to master
and slave going out of sync, as the order in which the rows
are retrieved from the table may differ on master and slave.
Solution: We mark writing to a table with auto_increment table
based on the rows selected from another table as unsafe. This
will cause the execution of such statements to throw a warning
and forces the statement to be logged in ROW if the logging
format is mixed.
Changes:
1. All the statements that writes to a table with auto_increment
column(s) based on the rows fetched from another table, will now
be unsafe.
2. CREATE TABLE with SELECT will now be unsafe.
sql/share/errmsg-utf8.txt:
Added new warning messages.
sql/sql_base.cc:
-Created function to check statements that write to
tables with auto_increment column and has select.
-Marked all the statements that write to a table
with auto_increment column based on rows fetched
from other table(s) as unsafe.
sql/sql_table.cc:
mark CREATE TABLE[with auto_increment column] as unsafe.
The problem was that wrong structure of mysql.event was not detected and
the server continued to use wrongly-structured data.
The fix is to check the structure of mysql.event after opening before
any use. That makes operations with events more strict -- some operations
that might work before throw errors now. That seems to be Ok.
Another side-effect of the patch is that if mysql.event is corrupted,
unrelated DROP DATABASE statements issue an SQL warning about inability
to open mysql.event table.