Merge from Percona Server enforced use of a specific storage engine
authored by Stewart Smith.
Modified to be session variable and modifiable only by SUPER. Use
similar implementation as default_storage_engine.
MASTER_GTID_WAIT function needs some status to evaluate its use.
master_gtid_wait_count indicates how many times the function is called.
master_gtid_wait_time indicates how much time in microseconds occurred
waiting (or timing out)
master_gtid_timeouts indicates how many time times this function timed
out rather than all successful gtids events being available.
Show total execution time (r_total_time_ms) for various parts of the
query:
1. time spent in SELECTs
2. time spent reading rows from storage engines
#2 currently gets the data from P_S.
log-tc-size is 24K by default. Page size is 64K on PPC64. But log-tc-
size
must be at least 3 x page size. This is enforced by TC_LOG_MMAP::open()
with a comment: to guarantee non-empty pool.
This all makes server not startable in default configuration on PPC64.
Autosize log-tc-size, so that it's min value= page size * 3, default
value= page size * 6, block size= page size.
Conflicts:
mysql-test/suite/sys_vars/inc/sysvars_server.inc
mysql-test/suite/sys_vars/r/sysvars_server_notembedded.result
mysql-test/t/mysqld--help.test
sql/mysqld.cc
sql/sys_vars.cc
Adjust the configuration options, as discussed on the
maria-developers@ mailing list.
The option to hint a transaction to not be replicated in parallel is
now called @@skip_parallel_replication, consistent with
@@skip_replication.
And the --slave-parallel-mode is now simplified to have just one of
the following values:
none
minimal
conservative
optimistic
aggressive
This reflects successively harder efforts to find opportunities to run
things in parallel on the slave. It allows to extend the server with
more automatic heuristics in the future without having to introduce a
new configuration option for each and every one.
In versions 5.5 and 5.6 the MySQL version is not logged until
server is started and ready to accept connections. Exiting
server before this point will not have server version information
in the log. But in 5.7 code, we log a server version information
just after we prepare server_version string and logging is initialized.
For 5.5 and 5.6 code also adding this code to print server version
information.
Test results:
================
5.5
-----
Server version will be logged as below on server startup:
141218 8:45:48 [Note] /home/praveen/WorkDir/mysql_local/bug20052694/mysql/sql/mysqld (mysqld 5.5.42-debug-log) starting as process 19697 ...
5.6
----
Server version will be logged as below on server startup:
2014-12-18 09:08:43 0 [Note] /home/praveen/WorkDir/mysql_local/bug20052694/mysql-5.6/sql/mysqld (mysqld 5.6.23-debug-log) starting as process 18474 ...
* reset current_thd in THD::~THD, otherwise my_malloc_size_cb_func()
might access THD after it was destroyed.
* remove now redundant set_current_thd(0) calls that follow delete thd.
Stage "Filling schema table" is now properly shown in 'show processlist'
mysys/mf_keycache.c:
Simple cleanup with more comments
sql/lock.cc:
Return to original stage after mysql_lock_tables
Made 'Table lock' as a true stage
sql/sql_show.cc:
Restore original stage after get_schema_tables_result
better fix that doesn't make debug-dbug variable to disappear
from mysqld --help output (this fact is used by have_debug.inc)
and shows correctly what dbug value was set on the command line.
log-tc-size is 24K by default. Page size is 64K on PPC64. But log-tc-size
must be at least 3 x page size. This is enforced by TC_LOG_MMAP::open()
with a comment: to guarantee non-empty pool.
This all makes server not startable in default configuration on PPC64.
Autosize log-tc-size, so that it's min value= page size * 3, default
value= page size * 6, block size= page size.
Implement --semi-sync-master-wait-point=AFTER_SYNC|AFTER_COMMIT.
When AFTER_SYNC, the semi-sync wait will be done earlier, before the storage
engine commit rather than after. This means that a transaction will not be
visible on the master until at least one slave has received it.
Make the binlog dump threads not need to take LOCK_log while sending
binlog events to slave. Instead, a new LOCK_binlog_end_pos is used
just to coordinate tracking the current end-of-log.
This is a pre-requisite for MDEV-162, "Enhanced semisync
replication". It should also help reduce the contention on LOCK_log on
a busy master.
Also does some much-needed refactoring/cleanup of the related code in
the binlog dump thread.
Implement a new mode for parallel replication. In this mode, all transactions
are optimistically attempted applied in parallel. In case of conflicts, the
offending transaction is rolled back and retried later non-parallel.
This is an early-release patch to facilitate testing, more changes to user
interface / options will be expected. The new mode is not enabled by default.
use the same restriction for character_set_client on the command line
and from SQL.
Also: remove strange hack from thd_init_client_charset() that contradicted
the manual (collation_connection and character_set_result were not always set)
Do not allow server to start if binlog_format is set
to a format other than ROW. Also restrict the change
of GLOBAL/SESSION binlog_format value at runtime.
Do not allow server to start if binlog_format is set
to a format other than ROW. Also restrict the change
of GLOBAL/SESSION binlog_format value at runtime.
In parallel replication, threads can do two different waits for a prior
transaction. One is for the prior transaction to start commit, the other is
for it to complete commit.
It turns out that the same PSI_stage_info message was errorneously used in
both cases (probably a merge error), causing SHOW PROCESSLIST to be
misleading.
Fix by using correct, distinct message in each case.
Extend existing plugins to support
* SHOW QUERY_RESPONSE_TIME
* FLUSH QUERY_RESPONSE_TIME
* SHOW LOCALE
move userstat tables to use the new API instead of
hand-coded syntax
replace flag SHOW_VALUE_IN_HELP (that's not really an
independendent flag, as it should only be used for
NO_CMD_LINE sysvars) with a special getopt.id type.
* ignore the OPTIMIZER_SWITCH_ENGINE_CONDITION_PUSHDOWN bit
* issue a deprecation warning on 'engine_condition_pushdown=on'
* remove unused remains of the old pre-5.5 engine_condition_pushdown variable