except c2932.
Bug#37232 and bug#31183 were fixed in the 6.0 branch only.
They should be fixed in the plugin too, specially MySQL 6.0
is discontinued at this point.
------------------------------------------------------------------------
r2604 | inaam | 2008-08-21 09:37:06 -0500 (Thu, 21 Aug 2008) | 8 lines
branches/6.0 bug#37232
Relax locking behaviour for REPLACE INTO t SELECT ... FROM t1.
Now SELECT on t1 is performed as a consistent read when the isolation
level is set to READ COMMITTED.
Reviewed by: Heikki
------------------------------------------------------------------------
r2605 | inaam | 2008-08-21 09:59:33 -0500 (Thu, 21 Aug 2008) | 7 lines
branches/6.0
Added a comment to clarify why distinct calls to read MySQL binary
log file name and log position do not entail any race condition.
Suggested by: Heikki
------------------------------------------------------------------------
r2956 | inaam | 2008-11-04 04:47:30 -0600 (Tue, 04 Nov 2008) | 11 lines
branches/6.0 bug#31183
If the system tablespace runs out of space because 'autoextend' is
not specified with innodb_data_file_path there was no error message
printed to the error log. The client would get 'table full' error.
This patch prints an appropriate error message to the error log.
rb://43
Approved by: Marko
------------------------------------------------------------------------