This is a prerequisite patch required to remove Innodb's
thd_destructor_proxy thread.
The patch implement pre-shutdown functionality for handlers.
A storage engine might need to perform some work after all user
connections are shut down, but before killing off the plugins.
The reason is that an SE could still be using some of the
server infrastructure. In case of Innodb this would be purge threads,
that call into the server to calculate results of virtual function,
acquire MDL locks on tables, or possibly also use the audit plugins.
1. Removed TIMESTAMP/TRANSACTION unit auto-detection in favor of default TIMESTAMP.
Reasons:
1.1. rare practical use and doubtful advantage of such auto-detection;
1.2. it conflicts with MDEV-16226 (TRX_ID-based versioned tables performance improvement).
Needless check_unit membership removed.
2. SQL: versioning type handling refactoring
Vers_type_handler hierarchy stores versioning properties of type.
virtual Type_handler::vers() accesses specialization of
Vers_type_handler for specific type.
virtual Vers_type_handler::kind() returns versioning kind
(timestamp/trx_id).
Removed Type_handler::Vers_history_point_check_unit() in favor of
Type_handler::vers().
Renames:
require_timestamp() -> require_timestamp_error()
require_trx_id() -> require_trx_id_error()
EDIT by Alexander Barkov (@abarkov):
check_sys_fields() moved to Vers_type_handler::check_sys_fields()
* do not allow versioned table to be without versioned (non-system) fields
* prohibit changing field versioning, when removing table versioning
* handle CREATE...SELECT as well
* Collect and pass apply error data to provider
* Rollback failed transaction and continue operation if provider returns
SUCCESS
* MTR tests for inconsistency voting
MDEV-19486 and one more similar bug appeared because handler::write_row() interface
welcomes to modify buffer by storage engine. But callers are not ready for that
thus bugs are possible in future.
handler::write_row():
handler::ha_write_row(): make argument const
Make Field::is_equal() const and return bool as it's a naturally fitting
type for it. Also it's agrument was narrowed to Column_definition.
InnoDB can change type of some columns by itself. InnoDB-specific code used to
reside in Field_xxx:is_equal() methods. Now engine-specific stuff was
moved to a virtual methods of handler::can_convert{string,varstring,blob,geom}.
These methods are called by Field::can_be_converted_by_engine() which is a
double dispatch pattern.
Some InnoDB-specific code still resides in compare_keys_but_name(). It should
be moved from here someday to handler::compare_key_parts(...) or similar.
IS_EQUAL_WITH_REINTERPRET_COMPATIBLE_CHARSET
IS_EQUAL_WITH_REINTERPRET_COMPATIBLE_CHARSET_BUT_COLLATE: both was removed
IS_EQUAL_NO, IS_EQUAL_YES are not needed now and should be removed
along with deprecated handler::check_if_incompatible_data().
HA_EXTENDED_TYPES_CONVERSION: was removed as such logic is not needed now by
server code.
ALTER_COLUMN_EQUAL_PACK_LENGTH: was renamed to a more generic
ALTER_COLUMN_TYPE_CHANGE_BY_ENGINE
followup for be5c432a42
ha_partition::calculate_checksum() has to invoke calculate_checksum()
for partitions unconditionally, not under (HA_HAS_OLD_CHECKSUM | HA_HAS_NEW_CHECKSUM).
Because the server uses ::info() to ask for a live checksum, while
calculate_checksum() must, precisely, calculate it the slow way,
also for tables that don't have the live checksum at all.
Also, fix the compilation on Windows (ha_checksum/ulonglong type mix).
A read-only storage engine that stores it's data in (aws) S3
To store data in S3 one could use ALTER TABLE:
ALTER TABLE table_name ENGINE=S3
libmarias3 integration done by Sergei Golubchik
libmarias3 created by Andrew Hutchings
Rather than iterating global plugin collection, iterate THD local
collection. Removes two LOCK_plugin locks per connection.
Part of MDEV-19515 - Improve connect speed
Use thd_get_ha_data()/thd_set_ha_data() which protect against plugin
removal until it has THD ha_data.
Do not reset THD ha_data in ha_federatedx::disconnect(), cleaner approach
is to let ha_close_connection() do it.
Part of MDEV-19515 - Improve connect speed
Problem:
========
We have a Master/Master Setup on two servers, but are only writing to one of
those servers (so it is essentially Master/Slave) We upgraded from 10.1.* to
10.2.22 last week and starting with the upgrade, we are getting duplicate key
errors on the slave. BINLOG=mixed.
Analysis:
=========
This issue happens with LOCK TABLES and binlog_format=MIXED combination. When an
UNSAFE statement is encountered in 'MIXED' mode, it is logged in the form of
'ROW' format. For all the tables that are part of LOCK TABLES list their table maps
are written into the binary log. For each table in the list a check is
done to see if 'check_table_binlog_row_based_done' flag is set or not. If it is not set
a check process is initiated to see if table qualifies for row based binary
logging or not and 'check_table_binlog_row_based_done' is set. This flag will be
cleared at the time of closing thread tables.
But there can be special cases where the LOCK TABLES contains more number of
tables but the unsafe query is actually using subset of tables from LOCK TABLES
list.
For example: LOCK TABLES locks t1,t2,t3 but the unsafe statement makes use of
only two tables t1,t3. In this case the 'check_table_binlog_row_based_done' flag
is enabled for table 't2' while writing table map, but 'close_thread_tables'
function call will not reset this flag. Since the flag is not cleared for table
't2' even a safe statement which used t2 will be logged in the form of row based
format.
This leads to an assert on debug builds and causes duplicate entries in release
builds. In release builds a statement is logged in the form of both ROW and
STATEMENT format. This causes the slave to fail with duplicate key error.
Fix:
===
During 'close_thread_tables' when LOCK TABLE modes are active "ha_reset" is done
for all the tables which were part of current statement. As mentioned in the
example 'ha_reset' is called for tables 't1' and 't3'. This will clear the
'check_table_binlog_row_based_done' flag. At this point add a check for the rest
of the tables to see if 'check_table_binlog_row_based_done' is enabled or not.
If enabled clear the flag.
Some places didn't match the previous rules, making the Floor
address wrong.
Additional sed rules:
sed -i -e 's/Place.*Suite .*, Boston/Street, Fifth Floor, Boston/g'
sed -i -e 's/Suite .*, Boston/Fifth Floor, Boston/g'
make live checksum to be returned in handler::info(),
and slow table-scan checksum to be calculated in handler::checksum().
part of
MDEV-16249 CHECKSUM TABLE for a spider table is not parallel and saves all data in memory in the spider head by default