pre-locking.
The crash was caused by an implicit assumption in check_table_access() that
table_list parameter is always a part of lex->query_tables.
When iterating over the passed list of tables, check_table_access() used
to stop only when lex->query_tables_last_not_own was reached.
In case of pre-locking, lex->query_tables_last_own is not NULL and points
to some element of lex->query_tables. When the parameter
of check_table_access() was not part of lex->query_tables, loop invariant
could never be violated and a crash would happen when the current table
pointer would point beyond the end of the provided list.
The fix is to change the signature of check_table_access() to also accept
a numeric limit of loop iterations, similarly to check_grant(), and
supply this limit in all places when we want to check access of tables
that are outside lex->query_tables, or just want to check access to one table.
Main problem: mysql 5.1 cannot read binlogs from 4.1.
Subproblem 1: There is a mistake in sql_ex_info::init. The read_str()
function updates its first argument to point to the next character to
read. However, it is applied only to a copy of the buffer pointer, so the
real buffer pointer is not updated.
Fix 1: do not take a copy of the buffer pointer. The copy was needed
because sql_ex_info::init does not use the const attribute on some of its
arguments. So we add the const attribute, too.
Subproblem 2: The first BINLOG statement is asserted to be a
FORMAT_DESCRIPTION_LOG_EVENT, but 4.1 binlogs begin with START_EVENT_V3.
Fix 2: allow START_EVENT_V3 too.
The problem is that the Table_locks_waited was incremented only
when the lock request succeed. If a thread waiting for the lock
gets killed or the lock request is aborted, the variable would
not be incremented, leading to inaccurate values in the variable.
The solution is to increment the Table_locks_waited whenever the
lock request is queued. This reflects better the intended behavior
of the variable -- show how many times a lock was waited.
Two disjuncts containing equalities of the form key=const1 and key=const2 can
be merged into one if const1 is equal to const2. To check it the common
collation of the constants were used rather than the collation of the field key.
For example when the default collation of the constants was cases insensitive
while the collation of the field was case sensitive, then two or-ed equality
predicates key='b' and key='B' incorrectly were merged into one f='b'. As a
result ref access was used instead of range access and wrong result sets were
returned in many cases.
Fixed the problem by comparing constant in the or-ed predicate with collation of
the key field.
"Plugin enum variables can't be set from command line"
fix crash of LOCK_plugins mutex when loading plug-ins from command line.
fix off-by-one bug when loading multiple plug-ins from the command line.
initialize command line handling for ENUM and SET plugin variable types.
require SQL_BIG_SELECTS=1
There was a previous test that leaves a non-default (small) max_join_size.
Fixed by re-setting the max_join_size to default when the test is over.
Changed to use information_schema to check auto_increment
Ndb.cpp:
Bug #33534 Bad performance of INSERT's in auto_incremented tables: Saving highest seen value when setting auto_increment fields
ndb_auto_increment.result:
Regenerated result
The problem is when create/rename/drop users, the statement was logged regardless of error, even if no data has been changed, the statement was logged.
After this patch, create/rename/drop users don't write the binlog if the statement makes no changes, if the statement does make any changes, log the statement with possible error code.
This patch is based on the patch for BUG#29749, which is not pushed