The method to purge binary log files produces different results in some platforms.
The reason is that the purge time is calculated based on table modified time and
that can't guarantee to purge master-bin.000002 in all platforms.(eg. windows)
Use a new way that sets the time to purge binlog file 1 second after the last
modified time of master-bin.000002.
That can be sure that the file is always deleted in any platform.
mysql-test/suite/rpl/r/rpl_rotate_logs.result:
Test result
mysql-test/suite/rpl/t/rpl_rotate_logs.test:
Test file
Bug #43203 Overflow from auto incrementing causes server segv
Detailed revision comments:
r4325 | sunny | 2009-03-02 02:28:52 +0200 (Mon, 02 Mar 2009) | 10 lines
branches/5.1: Bug#43203: Overflow from auto incrementing causes server segv
It was not a SIGSEGV but an assertion failure. The assertion was checking
the invariant that *first_value passed in by MySQL doesn't contain a value
that is greater than the max value for that type. The assertion has been
changed to a check and if the value is greater than the max we report a
generic AUTOINC failure.
rb://93
Approved by Heikki
Bug #42714 AUTO_INCREMENT errors in 5.1.31
Detailed revision comments:
r4287 | sunny | 2009-02-25 05:32:01 +0200 (Wed, 25 Feb 2009) | 10 lines
branches/5.1: Fix Bug#42714 AUTO_INCREMENT errors in 5.1.31. There are two
changes to the autoinc handling.
1. To fix the immediate problem from the bug report, we must ensure that the
value written to the table is always less than the max value stored in
dict_table_t.
2. The second related change is that according to MySQL documentation when
the offset is greater than the increment, we should ignore the offset.
Bug #42400 InnoDB autoinc code can't handle floating-point columns
Detailed revision comments:
r4065 | sunny | 2009-01-29 16:01:36 +0200 (Thu, 29 Jan 2009) | 8 lines
branches/5.1: In the last round of AUTOINC cleanup we assumed that AUTOINC
is only defined for integer columns. This caused an assertion failure when
we checked for the maximum value of a column type. We now calculate the
max value for floating-point autoinc columns too.
Fix Bug#42400 - InnoDB autoinc code can't handle floating-point columns
rb://84 and Mantis issue://162
r4111 | sunny | 2009-02-03 22:06:52 +0200 (Tue, 03 Feb 2009) | 2 lines
branches/5.1: Add the ULL suffix otherwise there is an overflow.
normalize error-messages
mysql-test/r/variables.result:
show that warning uses underscore
(sysvar-name), not hyphens (option-name)
mysql-test/t/variables.test:
show that warning uses underscore
(sysvar-name), not hyphens (option-name)
sql/set_var.cc:
normalize error-messages
Since there is more than one duplicate value in the table, when adding the
unique index it is not deterministic which value will be reported as causing a
problem. Replace the reported value with '' so that it doesn't affect the
results.
The problem is that creating a event could fail if the value of
the variable server_id didn't fit in the originator column of
the event system table. The cause is two-fold: it was possible
to set server_id to a value outside the documented range (from
0 to 2^32-1) and the originator column of the event table didn't
have enough room for values in this range.
The log tables (general_log and slow_log) also don't have a proper
column type to store the server_id and having a large server_id
value could prevent queries from being logged.
The solution is to ensure that all system tables that store the
server_id value have a proper column type (int unsigned) and that
the variable can't be set to a value that is not within the range.
mysql-test/r/events_bugs.result:
Add test case result for Bug#36540
mysql-test/r/log_tables.result:
Update column type.
mysql-test/r/system_mysql_db.result:
Update column type.
mysql-test/r/variables.result:
Add test case result for server_id value range.
mysql-test/suite/sys_vars/r/server_id_basic_64.result:
Update test case results.
mysql-test/t/events_bugs.test:
Add test case for Bug#36540
mysql-test/t/log_tables.test:
Fix column type.
mysql-test/t/variables.test:
Add test case for server_id value range.
scripts/mysql_system_tables.sql:
Columns that store the server_id value must be of type INT UNSIGNED,
fix event (originator), general_log and slow_log (server_id) tables
in accordance.
scripts/mysql_system_tables_fix.sql:
Columns that store the server_id value must be of type INT UNSIGNED,
fix event (originator), general_log and slow_log (server_id) tables
in accordance.
sql/mysqld.cc:
Set min and max values for the server_id variable.
Unfortunately we can't easily change server_id variable type
from ulong to uint32 because of the sys_var classes.
mysql-test/r/index_merge_myisam.result:
Testcases
mysql-test/t/index_merge_myisam.test:
Testcases
sql/strfunc.cc:
Change optimizer_switch from no_xxx to xxx=on/xx=off.
- Add functions to parse the new syntax
The copy of the original arguments of a aggregate function was not
initialized until after fix_fields().
Sometimes (e.g. when there's an error processing the statement)
the print() can be called with no corresponding fix_fields() call.
Fixed by adding a check if the Item is fixed before using the arguments
copy.
mysql-test/r/explain.result:
Bug #43354: test case
mysql-test/t/explain.test:
Bug #43354: test case
sql/item_sum.cc:
Bug #43354: use the argument list copy only if it's initialized
The method to purge binary log files produces different results in some platforms.
The reason is that the purge time is calculated based on table modified time and
that can't guarantee to purge master-bin.000002 in all platforms.(eg. windows)
Use a new way that sets the time to purge binlog file 1 second after the last modified time of master-bin.000002.
That can be sure that the file is always deleted in any platform.
mysql-test/suite/rpl/r/rpl_rotate_logs.result:
Test result
mysql-test/suite/rpl/t/rpl_rotate_logs.test:
Change 'purge time' 1 sencond after the last modified time of master-bin.000002.
--ignore-table option
mysqldump would correctly omit temporary tables for views, but would
incorrectly still emit all CREATE VIEW statements.
Backport a fix from 5.1, where we capture the names we want to emit
views for in one pass (the placeholder tables) and in the pass where
we actually emit the views, we don't emit a view if it wasn't in that
list.
test-fixes for 32-bit
mysql-test/t/variables.test:
Test for 10351 ("Max_Heap_Table_Size cannot be set to 4 gb")
now throws a warning on 32-bit, as it should. As we're not
actually interested in the warning but only in whether the
variable is set to a correct value afterwards, we disable
warnings for the duration of that test case so we won't have
to split the test into a 32-bit and a 64-bit flavour for no
real reason.
The reason of the bug is in that the test makes a trick with relay log files and
did not reset fully at the end.
If mtr does not restart the test the new SQL thread tried to work with the old time
session data.
Fixed with deploying RESET slave at the clean-up.
mysql-test/suite/binlog/t/binlog_auto_increment_bug33029.test:
adding RESET slave to force active mi and rli data struct to be reset.
The slave SQL thread will deal with a fresh structures each time it restarts.
When using mixed mode the record values stored inside the storage
engine differed from the ones computed from the row event. This
happened because the prepare_record function was calling
empty_record macro causing some don't care bits to be left set.
Replacing the empty_record plus explicitly setting defaults with
restore_record to restore the record default values fixes this.