Unfortunate DROP TEMPORARY..IF EXISTS on a regular table may allow
subsequent CREATE TABLE statements to steal away the PFS_table_share
instance from the dropped table.
This allows one to run the test suite even if any of the following
options are changed:
- character-set-server
- collation-server
- join-cache-level
- log-basename
- max-allowed-packet
- optimizer-switch
- query-cache-size and query-cache-type
- skip-name-resolve
- table-definition-cache
- table-open-cache
- Some innodb options
etc
Changes:
- Don't print out the value of system variables as one can't depend on
them to being constants.
- Don't set global variables to 'default' as the default may not
be the same as the test was started with if there was an additional
option file. Instead save original value and reset it at end of test.
- Test that depends on the latin1 character set should include
default_charset.inc or set the character set to latin1
- Test that depends on the original optimizer switch, should include
default_optimizer_switch.inc
- Test that depends on the value of a specific system variable should
set it in the test (like optimizer_use_condition_selectivity)
- Split subselect3.test into subselect3.test and subselect3.inc to
make it easier to set and reset system variables.
- Added .opt files for test that required specfic options that could
be changed by external configuration files.
- Fixed result files in rockdsb & tokudb that had not been updated for
a while.
Crash happened because in discover, table->work_part_info was not properly
reset before execution.
Fixed by resetting before calling execute alter table, create table or
mysql_create_frm_image.
Also fix perfschema.hostcache_ipv6_max_con.
The test case makes use of a debug switch to execute some special code.
The code does hostname replacement. Every hostname sent during connect
phase becomes santa.claus.ipv4.example.com (or ipv6). This causes a
connection from root@localhost to fail, as root is not registered as
santa claus user. The failure is only apparent on Windows as Unix
systems make use of sockets, which bypass the name resolution check
entirely.
MDEV--15609 engines/funcs.crash_manytables_number crashes with error 24
(too many open files)
MDEV-10286 Adjustment of table_open_cache according to system limits
does not work when open-files-limit option is provided
Fixed by adjusting tc_size downwards if there is not enough file
descriptors to use.
Other changes:
- Ensure that there is 30 (was 10) extra file descriptors for other usage
- Decrease TABLE_OPEN_CACHE_MIN to 200 as it's better to have a smaller
table cache than getting error 24
- Increase minimum of max_connections and table_open_cache from 1 to 10
as 1 is not usable for any real application, only for testing.
This was done in, among other things:
- thd->db and thd->db_length
- TABLE_LIST tablename, db, alias and schema_name
- Audit plugin database name
- lex->db
- All db and table names in Alter_table_ctx
- st_select_lex db
Other things:
- Changed a lot of functions to take const LEX_CSTRING* as argument
for db, table_name and alias. See init_one_table() as an example.
- Changed some function arguments from LEX_CSTRING to const LEX_CSTRING
- Changed some lists from LEX_STRING to LEX_CSTRING
- threads_mysql.result changed because process list_db wasn't always
correctly updated
- New append_identifier() function that takes LEX_CSTRING* as arguments
- Added new element tmp_buff to Alter_table_ctx to separate temp name
handling from temporary space
- Ensure we store the length after my_casedn_str() of table/db names
- Removed not used version of rename_table_in_stat_tables()
- Changed Natural_join_column::table_name and db_name() to never return
NULL (used for print)
- thd->get_db() now returns db as a printable string (thd->db.str or "")
and specifically the ack receiving functionality.
Semisync is turned to be static instead of plugin so its functions
are invoked at the same points as RUN_HOOKS.
The RUN_HOOKS and the observer interface remain to be removed by later
patch.
Todo:
React on killed status by repl_semisync_master.wait_after_sync(). Currently
Repl_semi_sync_master::commit_trx does not check the killed status.
There were few bugfixes found that are present in mysql and its unclear
whether/how they are covered. Those include:
Bug#15985893: GTID SKIPPED EVENTS ON MASTER CAUSE SEMI SYNC TIME-OUTS
Bug#17932935 CALLING IS_SEMI_SYNC_SLAVE() IN EACH FUNCTION CALL
HAS BAD PERFORMANCE
Bug#20574628: SEMI-SYNC REPLICATION PERFORMANCE DEGRADES WITH A HIGH NUMBER OF THREADS
Part of MDEV-13073 AliSQL Optimize performance of semisync
The idea it to use a dedicated lock detecting if there is new data in
the master's binary log instead of the overused LOCK_log.
Changes:
- Use dedicated COND variables for the relay and binary log signaling.
This was needed as we where the old 'update_cond' variable was used
with different mutex's, which could cause deadlocks.
- Relay log uses now COND_relay_log_updated and LOCK_log
- Binary log uses now COND_bin_log_updated and LOCK_binlog_end_pos
- Renamed signal_cnt to relay_signal_cnt (as we now have two signals)
- Added some missing error handling in MYSQL_BIN_LOG::new_file_impl()
- Reformatted some comments with old style
- Renamed m_key_LOCK_binlog_end_pos to key_LOCK_binlog_end_pos
- Changed 'signal_update()' to update_binlog_end_pos() which works for
both relay and binary log
Part of MDEV-13073 AliSQL Optimize performance of semisync
Did the following renames to match other similar variables
key_ss_mutex_LOCK_binlog_ > key_LOCK_bing
key_ss_cond_COND_binlog_send_ -> key_COND_binlog_send
COND_binlog_send_ -> COND_binlog_send
LOCK_binlog_ -> LOCK_binlog
debian/mariadb-server-10.2.install does not install semisync libs.
LOCK_thd_data was used to protect both THD data and
ensure that the THD is not deleted while it was in use
This patch moves the THD delete protection to LOCK_thd_kill,
which already protects the THD for kill.
The benefits are:
- More well defined what LOCK_thd_data protects
- LOCK_thd_data usage is now much simpler and easier to verify
- Less chance of deadlocks in SHOW PROCESS LIST as there is less
chance of interactions between mutexes
- Remove not needed LOCK_thread_count from
thd_get_error_context_description()
- Fewer mutex taken for thd->awake()
Other things:
- Don't take mysys->var mutex in show processlist to check if thread
is kill marked
- thd->awake() now automatically takes the LOCK_thd_kill mutex
(Simplifies code)
- Apc uses LOCK_thd_kill instead of LOCK_thd_data
As reported in MDEV-11969 "there's no way to ditch knowledge" about some
domain that is no longer updated on a server. Besides being of annoyance to
clutter output in DBA console stale domains can prevent the slave
to connect the master as MDEV-12012 witnesses.
What domain is obsolete must be evaluated by the user (DBA) according
to whether the domain info is still relevant and will the domain ever
receive any update.
This patch introduces a method to discard obsolete gtid domains from
the server binlog state. The removal requires no event group from such
domain present in existing binlog files though. If there are any the
containing logs must be first PURGEd in order for
FLUSH BINARY LOGS DELETE_DOMAIN_ID=(list-of-domains)
succeed. Otherwise the command returns an error.
The list of obsolete domains can be computed through
intersecting two sets - the earliest (first) binlog's Gtid_list
and the current value of @@global.gtid_binlog_state - and extracting
the domain id components from the intersection list items.
The new DELETE_DOMAIN_ID featured FLUSH continues to rotate binlog
omitting the deleted domains from the active binlog file's Gtid_list.
Notice though when the command is ineffective - that none of requested to delete
domain exists in the binlog state - rotation does not occur.
Obsolete domain deletion is not harmful for connected slaves as long
as master side binlog files *purge* is synchronized with FLUSH-DELETE_DOMAIN_ID.
The slaves must have the last event from purged files processed as usual,
in order not to bump later into requesting a gtid from a file which
was already gone.
While the command is not replicated (as ordinary FLUSH BINLOG LOGS is)
slaves, even though having extra domains, won't suffer from reconnection errors
thanks to master-slave gtid connection protocol allowing the master
to be ignorant about a gtid domain.
Should at failover such slave to be promoted into master role it may run
the ex-master's
FLUSH BINARY LOGS DELETE_DOMAIN_ID=(list-of-domains)
to clean its own binlog state.
NOTES.
suite/perfschema/r/start_server_low_digest.result
is re-recorded as consequence of internal parser codes changes.
This was done to get more information about where time is spent.
Now we can get proper timing for time spent in commit, rollback,
binlog write etc.
Following stages was added:
- Commit
- Commit_implicit
- Rollback
- Rollback implicit
- Binlog write
- Init for update
- This is used instead of "Init" for insert, update and delete.
- Staring cleanup
Following stages where changed:
- "Unlocking tables" stage reset stage to previous stage at end
- "binlog write" stage resets stage to previous stage at end
- "end" -> "end of update loop"
- "cleaning up" -> "Reset for next command"
- Added stage_searching_rows_for_update when searching for rows
to be deleted.
Other things:
- Renamed all stages to start with big letter (before there was no
consitency)
- Increased performance_schema_max_stage_classes from 150 to 160.
- Most of the test changes in performance schema comes from renaming of
stages.
- Removed duplicate output of variables and inital state in a lot of
performance schema tests.
This was done to make it easier to change a default value for a
performance variable without affecting all tests.
- Added start_server_variables.test to check configuration
- Removed some duplicate "closing tables" stages
- Updated position for "stage_init_update" and "stage_updating" for
delete, insert and update to be just before update loop (for more
exact timing).
- Don't set "Checking permissions" twice in a row.
- Remove stage_end stage from creating views (not done for create table
either).
- Updated default performance history size from 10 to 20 because of new
stages
- Ensure that ps_enabled is correct (to be used in a later patch)
This is a 10.3 specific part of MDEV-13049.
It disables automatic sorting for
"SELECT .. FROM INFORMATION_SCHEMA.{SCHEMATA|TABLES}"
and adjusts the affected tests accordingly.