As agreed with Serg, renaming class Yesno to Yes_or_empty,
to reflect better its behavior.
This helper class is used to define INFORMATION_SCHEMA columns
that return either "Yes" or an empty string.
`m_status == DA_ERROR' failed on SELECT after setting tmp_disk_table_size.
Analysis: Mismatch in number of warnings between "194 warnings" vs
"64 rows in set" is because of max_error_count variable which has default
value of 64.
About the corrupted tables, the error that occurs because of insufficient
tmp_disk_table_size variable is not reported correctly and we continue to
execute the statement. But because the previous error (about table being
full)is not reported correctly, this error moves up the stack and is
wrongly reported as parsing error later on while parsing frm file of one
of the information schema table. This parsing error gives corrupted table
error.
As for the innodb error, it occurs even when tmp_disk_table_size is not
insufficient is default but the internal error handler takes care of it
and the error doesn't show. But when tmp_disk_table_size is insufficient,
the fatal error which wasn't reported correctly moves up the stack so
internal error handler is not called. So it shows errors.
Fix: Report the error correctly.
Problem:
DECIMAL columns in I_S must be explicitly set of some value.
I_S columns do not have `DEFAULT 0` (after MDEV-18918), so during
restore_record() their record fragments pointed by Field::ptr are
initialized to zero bytes 0x00.
But an array of 0x00's is not a valid binary DECIMAL value.
So val_decimal() called for such Field_new_decimal generated a warning
when seeing a wrong binary encoded DECIMAL value in the record.
Fix:
Explicitly setting INFORMATION_SCHEMA.PROCESSLIST.PROGRESS
to the decimal value of 0 if no progress information is available.
There were two independent problems which lead to the crash
and to the non-relevant records returned in I_S queries:
- The code in the I_S implementation was not secure
about values with 0x00 bytes.
It's fixed by using check_db_name() and check_table_name()
inside make_table_name_list(), and by adding the test for
0x00 inside check_table_name().
- The code in Item_string::print() did not convert
strings without introducers when restoring
the CREATE VIEW statement from an Item tree.
This made wrong literals inside the "query" line in the view FRM file
in cases when the VIEW parse time
character_set_client!=character_set_connection.
That's fixed by adding a proper conversion.
This change also fixed a similar problem in SHOW PROCEDURE CODE -
the literals were displayed in wrong character set in SP instructions
in cases when the SP parse time
character_set_client!=character_set_connection.
This is important since Sys_var_typelib and its descendants return
pointers to constant symbols from *_value_ptr, which are situated in
write-protected-memory.
* functions const-qualified:
- value_ptr
- session_value_ptr
- global_value_ptr
- default_value_ptr
- Sys_var_vers_asof::value_ptr
- other minor private ones
* remove C-style typecasts when it discards qualifiers
C:\projects\server\sql\sql_show.cc(7913): error C2220: warning treated as error - no 'object' file generated [C:\projects\server\win_build\sql\sql.vcxproj]
C:\projects\server\sql\sql_show.cc(7913): warning C4267: 'initializing': conversion from 'size_t' to 'uint', possible loss of data [C:\projects\server\win_build\sql\sql.vcxproj]
caused by 768c51880a