mysql client displays wrong character-set of server. When a user changes the
charset of a server, mysql client 'status' command displays wrong charset but
the command "SHOW VARIABLES LIKE "%charset%" displayed correct charset results.
The problem is only with the mysql client's 'status' command output.
In mysql client, the method mysql_store_lazy_result() returns 0 for
success and non-zero for failure. The method com_status() was using this method
wrongly. Fixed all such instances according to return value of the method
mysql_store_lazy_result().
client/mysql.cc:
Fix for BUG#47671 - wrong character-set after upgrade from 5.1.34 to 5.1.39
Fix com_status() method to use mysql_store_lazy_result() properly.
mysql-test/r/bug47671.result:
Fix for BUG#47671 - wrong character-set after upgrade from 5.1.34 to 5.1.39
Testcase for BUG#47671
mysql-test/t/bug47671-master.opt:
Fix for BUG#47671 - wrong character-set after upgrade from 5.1.34 to 5.1.39
Testcase for BUG#47671
mysql-test/t/bug47671.test:
Fix for BUG#47671 - wrong character-set after upgrade from 5.1.34 to 5.1.39
Testcase for BUG#47671
In RBR, All statements operating on temporary tables should not be binlogged.
Despite this fact, after executing 'TRUNCATE... ' on a temporary table,
the command is still logged, even if in row-based mode. Consequently, this raises
problems in the slave as the table may not exist, resulting in an
execution failure. Ultimately, this causes the slave to report
an error and abort.
After this patch, 'TRUNCATE ...' statement on a temporary table will not be
binlogged in RBR.
The problem is that the server could crash when attempting
to access a non-conformant proc system table. One such case
was a crash when invoking stored procedure related statements
on a 5.1 server with a proc system table in the 5.0 format.
The solution is to validate the proc system table format
before attempts to access it are made. If the table is not
in the format that the server expects, a message is written
to the error log and the statement that caused the table to
be accessed fails.
mysql-test/r/sp-destruct.result:
Add test case result for Bug#41726
mysql-test/t/sp-destruct.test:
Add test case for Bug#41726
sql/event_db_repository.cc:
Update code to use new structures.
sql/sp.cc:
Describe the proc table format and use it to validate when
opening a instance of the table.
Add a check to insure that a error message is written to
the error log only once.
sql/sql_acl.cc:
Remove unused variable and use new structure.
sql/sql_acl.h:
Export field definition.
sql/table.cc:
Accept the field count and definition in a single structure.
sql/table.h:
Combine the field count and definition in a single structure.
Transform function into a class in order to support different
ways of reporting a error.
Add a pointer cache to TABLE_SHARE.
Bug #48370 Absolutely wrong calculations with GROUP BY and
decimal fields when using IF
Added the test cases in the above two bugs for regression
testing.
Added additional tests that demonstrate a incomplete fix.
Added a new factory method for Field_new_decimal to
create a field from an (decimal returning) Item.
In the new method made sure that all the precision and
length variables are capped in a proper way.
This is required because Item's can have larger precision
than the decimal fields and thus need to be capped when
creating a field based on an Item type.
Fixed the wrong typecast to Item_decimal.
When merging ranges during calculation of the result of OR
to two range sets the current range may be obsoleted by the
resulting merged range.
The first overlapping range can be obsoleted as well.
Fixed by moving the pointer to the first overlapping range to the
pointer of the resulting union range.
Added few comments at key places in key_or().
Problem: Some system functions that could return different values on
master and slave were not marked unsafe. In particular:
GET_LOCK
IS_FREE_LOCK
IS_USED_LOCK
MASTER_POS_WAIT
RELEASE_LOCK
SLEEP
SYSDATE
VERSION
Fix: Mark these functions unsafe.
mysql-test/extra/rpl_tests/rpl_stm_000001.test:
- The test does not work in mixed mode any more, since it tries to
simulate an error in the sql thread in a query that uses get_lock.
Since get_lock now causes the query to be logged in row format,
the error didn't happen. Hence, we now force statement mode.
- Warnings must be disabled when the unsafe query is issued.
- Replaced some save_master_pos+connection slave+sync_with_master
by sync_slave_with_master.
mysql-test/suite/binlog/r/binlog_stm_mix_innodb_myisam.result:
updated result file
mysql-test/suite/binlog/r/binlog_stm_row.result:
updated result file
mysql-test/suite/binlog/r/binlog_unsafe.result:
updated result file
mysql-test/suite/binlog/t/binlog_killed.test:
binlog_killed only works in statement format now, since
it switches to row mode in mixed mode.
mysql-test/suite/binlog/t/binlog_stm_mix_innodb_myisam.test:
suppress warnings for unsafe statements
mysql-test/suite/binlog/t/binlog_stm_row.test:
- Suppress warnings in test that causes warnings.
- The test sets binlog format explicitly, so no need to execute it
twice.
mysql-test/suite/binlog/t/binlog_unsafe.test:
Added test for all unsafe system functions. This test also includes
system functions that were unsafe prior to BUG#47995.
mysql-test/suite/rpl/r/rpl_err_ignoredtable.result:
updated result file
mysql-test/suite/rpl/r/rpl_get_lock.result:
updated result file
mysql-test/suite/rpl/r/rpl_nondeterministic_functions.result:
new result file
mysql-test/suite/rpl/r/rpl_stm_000001.result:
updated result file
mysql-test/suite/rpl/r/rpl_trigger.result:
updated result file
mysql-test/suite/rpl/t/rpl_err_ignoredtable.test:
- suppress warnings for unsafe statement
- replaced save_master_pos+connection slave+sync_with_master
with sync_slave_with_master
mysql-test/suite/rpl/t/rpl_get_lock.test:
update test case that causes new warnings
mysql-test/suite/rpl/t/rpl_nondeterministic_functions.test:
Added new test case for nondeterministic functions.
mysql-test/suite/rpl/t/rpl_trigger.test:
update test case that causes new warnings
sql/item_create.cc:
Marked some system functions unsafe.
sql/item_strfunc.cc:
Clarified comment related to this bug.
sql/sql_yacc.yy:
Marked sysdate unsafe.
Fixed a problem with the test case when executed with ps-protocol.
There the conflicing lock would be noticed during prepare, not
during execution of the insert - leading to a different (but
equally appropriate) error message.
DELETE IGNORE
The ER_CANT_UPDATE_USED_TABLE_IN_SF_OR_TRG error was set in the
diagnostics area when it happened, but the DELETE cleanup code
never checked for a non-fatal error condition, thus trying to
set diag.area to "ok". This triggered an assert checking that
the diag.area was empty.
The fix was to test if there existed a non-fatal error condition
(thd->is_error() before ok'ing the operation.
The problem was a "self-deadlock" if the connection issuing INSERT DELAYED
had both the global read lock (FLUSH TABLES WITH READ LOCK) and LOCK TABLES
mode active. The table being inserted into had to be different from the
table(s) locked by LOCK TABLES.
For INSERT DELAYED, the connection thread waits until the handler thread has
opened and locked its table before returning. But since the global read lock
was active, the handler thread would be unable to lock and would wait for the
global read lock to go away.
So the handler thread would be waiting for the connection thread to release
the global read lock while the connection thread was waiting for the handler
thread to lock the table. This gave a "self-deadlock" (same connection,
different threads).
The deadlock would only happen if we also had LOCK TABLES mode since the
INSERT otherwise will try to get protection against global read lock before
starting the handler thread. It will then notice that the global read lock
is owned by the same connection and report ER_CANT_UPDATE_WITH_READLOCK.
This patch removes the deadlock by reporting ER_CANT_UPDATE_WITH_READLOCK
also if we are inside LOCK TABLES mode.
Test case added to delayed.test.
sql/sql_partition.cc:
Bug#45904 Used list_of_part_fields instead of list_of_subpart_fields to discover if KEY subpartitioning => caused failure when charset=utf8 even for subpartitioning by key, would also allow for subpartitioning by hash with utf8 erroneously
to the client connection, not to the error log. This change will allow
innodb-index.test to be re-enabled. It was previously disabled, because
mysql-test-run does not like output in the error log.
row_create_table_for_mysql(): Do not output anything to the error log
when reporting DB_DUPLICATE_KEY. Let the caller report the error.
Add a TODO comment that the dict_table_t object is apparently not freed
when an error occurs.
create_table_def(): Convert InnoDB table names to the character set
of the client connection for reporting. Use my_error(ER_WRONG_COLUMN_NAME)
for reporting reserved column names. Report my_error(ER_TABLE_EXISTS_ERROR)
when row_create_table_for_mysql() returns DB_DUPLICATE_KEY.
rb://206
WHERE conditions
check_group_min_max() checks if the loose index scan
optimization is applicable for a given WHERE condition, that is
if the MIN/MAX attribute participates only in range predicates
comparing the corresponding field with constants.
The problem was that it considered the whole predicate suitable
for the loose index scan optimization as soon as it encountered
a constant as a predicate argument. This is obviously wrong for
cases when a constant is the first argument of a predicate
which does not satisfy the above condition.
Fixed check_group_min_max() so that all arguments of the input
predicate are considered to decide if it passes the test, even
though a constant has already been encountered.
mysql-test/r/group_min_max.result:
Added a test case for bug #48472.
mysql-test/t/group_min_max.test:
Added a test case for bug #48472.
sql/opt_range.cc:
Fixed check_group_min_max() so that all arguments of the input
predicate are considered to decide if it passes the test, even
though a constant has already been encountered.
MySQL manual describes values of the YEAR(2) field type as follows:
values 00 - 69 mean 2000 - 2069 years and values 70 - 99 mean 1970 - 1999
years. MIN/MAX and comparison functions was comparing them as int values
thus producing wrong result.
Now the Arg_comparator class is extended with compare_year function which
performs correct comparison of the YEAR type.
The Item_sum_hybrid class now uses Item_cache and Arg_comparator objects to
correctly calculate its value.
To allow Arg_comparator to use func_name() function for Item_func and Item_sum
objects the func_name declaration is moved to the Item_result_field class.
A helper function is_owner_equal_func is added to the Arg_comparator class.
It checks whether the Arg_comparator object owner is the <=> function or not.
A helper function setup is added to the Item_sum_hybrid class. It sets up
cache item and comparator.
mysql-test/r/func_group.result:
Added a test case for the bug#43668.
mysql-test/t/func_group.test:
Added a test case for the bug#43668.
sql/item.cc:
Bug#43668: Wrong comparison and MIN/MAX for YEAR(2)
Now Item_cache_int returns the type of cached item.
sql/item.h:
Bug#43668: Wrong comparison and MIN/MAX for YEAR(2)
To allow Arg_comparator to use func_name() function for Item_func and Item_sum
objects the func_name declaration is moved to the Item_result_field class.
sql/item_cmpfunc.cc:
Bug#43668: Wrong comparison and MIN/MAX for YEAR(2)
The Arg_comparator class is extended with compare_year function which
performs correct comparison of the YEAR type.
sql/item_cmpfunc.h:
Bug#43668: Wrong comparison and MIN/MAX for YEAR(2)
The year_as_datetime variable is added to the Arg_comparator class.
It's set to TRUE when YEAR value should be converted to the
YYYY-00-00 00:00:00 format for correct YEAR-DATETIME comparison.
sql/item_geofunc.cc:
Bug#43668: Wrong comparison and MIN/MAX for YEAR(2)
Item_func_spatial_rel::val_int chenged to use Arg_comparator's string
buffers.
sql/item_subselect.h:
Bug#43668: Wrong comparison and MIN/MAX for YEAR(2)
Added an implementation of the virtual func_name function.
sql/item_sum.cc:
Bug#43668: Wrong comparison and MIN/MAX for YEAR(2)
The Item_sum_hybrid class now uses Item_cache and Arg_comparator objects to
correctly calculate its value.
A helper function setup is added to the Item_sum_hybrid class. It sets up
cache item and comparator.
sql/item_sum.h:
Bug#43668: Wrong comparison and MIN/MAX for YEAR(2)
The Item_sum_hybrid class now uses Item_cache and Arg_comparator objects to
correctly calculate its value.
Added an implementation of the virtual func_name function.
At the end of innodb-index.test: restore the environment as it was before
the test was started to silence this warning:
MTR's internal check of the test case 'main.innodb-index' failed.
This means that the test case does not preserve the state that existed
before the test case was executed. Most likely the test case did not
do a proper clean-up.
This is the diff of the states of the servers before and after the
test case was executed:
mysqltest: Logging to '/tmp/autotest.sh-20091117_033000-zip.btyZwu/mysql-5.1/mysql-test/var/tmp/check-mysqld_1.log'.
mysqltest: Results saved in '/tmp/autotest.sh-20091117_033000-zip.btyZwu/mysql-5.1/mysql-test/var/tmp/check-mysqld_1.result'.
mysqltest: Connecting to server localhost:13000 (socket /tmp/autotest.sh-20091117_033000-zip.btyZwu/mysql-5.1/mysql-test/var/tmp/mysqld.1.sock) as 'root', connection 'default', attempt 0 ...
mysqltest: ... Connected.
mysqltest: Start processing test commands from './include/check-testcase.test' ...
mysqltest: ... Done processing test commands.
--- /tmp/autotest.sh-20091117_033000-zip.btyZwu/mysql-5.1/mysql-test/var/tmp/check-mysqld_1.result 2009-11-17 13:10:40.000000000 +0300
+++ /tmp/autotest.sh-20091117_033000-zip.btyZwu/mysql-5.1/mysql-test/var/tmp/check-mysqld_1.reject 2009-11-17 13:10:54.000000000 +0300
@@ -84,7 +84,7 @@
INNODB_DOUBLEWRITE ON
INNODB_FAST_SHUTDOWN 1
INNODB_FILE_FORMAT Antelope
-INNODB_FILE_FORMAT_CHECK Antelope
+INNODB_FILE_FORMAT_CHECK Barracuda
INNODB_FILE_PER_TABLE OFF
INNODB_FLUSH_LOG_AT_TRX_COMMIT 1
INNODB_FLUSH_METHOD
mysqltest: Result content mismatch
not ok
init_read_record() - (records.cc:274)
Item_cond::used_tables_cache was accessed in
records.cc#init_read_record() without being initialized. It had
not been initialized because it was wrongly assumed that the
Item's variables would not be accessed, and hence
quick_fix_field() was used instead of fix_fields() to save a few
CPU cycles at creation time.
The fix is to properly initilize the Item by replacing
quick_fix_field() with fix_fields().
mysql-test/r/select.result:
Add test for BUG#48052
mysql-test/t/select.test:
Add test for BUG#48052
sql/sql_select.cc:
Properly initialize Item_cond_and by calling fix_fields (instead of quick_fix_field) when the Item that "ANDs" WHERE clause conditions with HAVING clause conditions is created.
From BUG 34582 commit message:
Issuing 'FLUSH LOGS' does not close and reopen indexfile.
Instead a SEEK_SET is performed.
This patch makes index file to be closed and reopened whenever a
rotation happens (FLUSH LOGS is issued or binary log exceeds
maximum configured size).
This patch borrows ideas, text and code from Kristofer
Pettersson's patch.
An assignment of a system variable sharing the same base
name as a declared stored procedure variable in the same
context could lead to a crash.
The reason was that during the parsing of the syntactic
rule 'option_value' an uninitialized set_var object was
pushed to the parameter stack of the SET statement. The
parent rule 'option_type_value' interpreted the existence
of variables on the parameter stack as an assignment and
wrapped it in a sp_instr_set object.
As the procedure later was executed an attempt was made
to run the method 'check()' on an uninitialized member
object (NULL value) belonging to the previously created
but uninitialized object.
This patch refactors the 'internal_variable_name' rule and
copies the semantic analysis part to the depending parent
rule: 'option_value'. This makes it possible to account
for any prefixes affecting the interpretation of the
internal_variable_name.
mysql-test/r/sp.result:
Add test case result.
mysql-test/t/sp.test:
Add test case for bug.
sql/sql_yacc.yy:
- Reduce churn in rule sys_option_value by moving to
specialized functions.
- Comment the the lookup in the rule internel_variable_name
is a best effort operation.
- Lookup for a system variable in the option_value if one was
not found (the variable could have been shadowed)
Until-pos guarding did not distiguish the master originated events from ones that the slave
can introduce to the relay log e.g Rotate to the next relay log at slave restarting.
The local Rotate's coordinate are incomparable with the Until-master-pos.
That led to the unexpectable stop this bug describes.
Fixed with to avoid Until-master-pos comparison for a local slave's event.
Notice that if --replicate-same-server is true such event is treated as coming from
the master side.
mysql-test/r/rpl_until.result:
results changed.
mysql-test/t/rpl_until.test:
regression test for bug#47210 is added.
sql/slave.cc:
st_relay_log_info::is_until_satisfied() is augmented with avoidance of
Until-master-pos comparison for a local slave's event.
if --replicate-same-server is true such event is treated as coming from
the master side.
sql/slave.h:
signature of is_until_satisfied() changed to supply THD and Event to the routine.