mysql-test/suite/heap/heap.result:
Added test case for MDEV-436
mysql-test/suite/heap/heap.test:
Added test case for MDEV-436
storage/heap/hp_block.c:
Don't allocate a set of HP_PTRS when not needed. This saves us about 1024 bytes for most allocations.
storage/heap/hp_create.c:
Made the initial allocation of block sizes depending on min_records and max_records.
mysql_rm_table_no_locks() function was modified.
When we construct log record for the DROP TABLE, now we
look if there's a comment before the first table name and
add it to the record if so.
per-file comments:
sql/sql_table.cc
MDEV-340 Save replication comments for DROP TABLE.
comment_length() function implemented to find comments in the query,
call it in mysql_rm_table_no_locks() and use the result to form log record.
mysql-test/suite/binlog/r/binlog_drop_if_exists.result
MDEV-340 Save replication comments for DROP TABLE.
test result updated.
mysql-test/suite/binlog/t/binlog_drop_if_exists.test
MDEV-340 Save replication comments for DROP TABLE.
test case added.
Following reasons caused mismatches:
- different handling of invalid values;
- different CAST results with fractional seconds;
- microseconds support in MariaDB;
- different algorithm of comparing temporal values;
- differences in error and warning texts and codes;
- different approach to truncating datetime values to time;
- additional collations;
- different record order for queries without ORDER BY;
- MySQL bug#66034.
More details in MDEV-369 comments.
Problem description:
Table 't' created with two colums having compound index on both the
columns under innodb/myisam engine at remote machine. In the local
machine same table is created undet the federated engine.
A select having where clause with along 'AND' operation gives wrong
results on local machine.
Analysis:
The given query at federated engine is wrongly transformed by
federated::create_where_from_key() function and the same was sent to
the remote machine. Hence the local machine is showing wrong results.
Given query "select c1 from t where c1 <= 2 and c2 = 1;"
Query transformed, after ha_federated::create_where_from_key() function is:
SELECT `c1`, `c2` FROM `t` WHERE (`c1` IS NOT NULL ) AND
( (`c1` >= 2) AND (`c2` <= 1) ) and the same sent to real_query().
In the above the '<=' and '=' conditions were transformed to '>=' and
'<=' respectively.
ha_federated::create_where_from_key() function behaving as below:
The key_range is having both the start_key and end_key. The start_key
is used to get "(`c1` IS NOT NULL )" part of the where clause, this
transformation is correct. The end_key is used to get "( (`c1` >= 2)
AND (`c2` <= 1) )", which is wrong, here the given conditions('<=' and '=')
are changed as wrong conditions('>=' and '<=').
The end_key is having {key = 0x39fa6d0 "", length = 10, keypart_map = 3,
flag = HA_READ_AFTER_KEY}
The store_length is having value '5'. Based on store_length and length
values the condition values is applied in HA_READ_AFTER_KEY switch case.
The switch case 'HA_READ_AFTER_KEY' is applicable to only the last part of
the end_key and for previous parts it is going to 'HA_READ_KEY_OR_NEXT' case,
here the '>=' is getting added as a condition instead of '<='.
Fix:
Updated the 'if' condition in 'HA_READ_AFTER_KEY' case to affect for all
parts of the end_key. i.e 'i > 0' will used for end_key, Hence added it in
the if condition.
mysql-test/suite/federated/federated.test:
modified the federated.inc file location
mysql-test/suite/federated/federated_archive.test:
modified the federated.inc file location
mysql-test/suite/federated/federated_bug_13118.test:
modified the federated.inc file location
mysql-test/suite/federated/federated_bug_25714.test:
modified the federated.inc file location
mysql-test/suite/federated/federated_bug_35333.test:
modified the federated.inc file location
mysql-test/suite/federated/federated_debug.test:
modified the federated.inc file location
mysql-test/suite/federated/federated_innodb.test:
modified the federated.inc file location
mysql-test/suite/federated/federated_server.test:
modified the federated.inc file location
mysql-test/suite/federated/federated_transactions.test:
modified the federated.inc file location
mysql-test/suite/federated/include/federated.inc:
moved the file from federated suite to federated/include folder
mysql-test/suite/federated/include/federated_cleanup.inc:
moved the file from federated suite to federated/include folder
mysql-test/suite/federated/include/have_federated_db.inc:
moved the file from federated suite to federated/include folder
storage/federated/ha_federated.cc:
updated the 'if condition' in ha_federated::create_where_from_key()
function.
Backporting the WL#5716, "Information schema table for InnoDB
buffer pool information". Backporting revisions 2876.244.113,
2876.244.102 from mysql-trunk.
rb://1175 approved by Jimmy Yang.
Backporting the WL#5716, "Information schema table for InnoDB
buffer pool information". Backporting revisions 2876.244.113,
2876.244.102 from mysql-trunk.
rb://1177 approved by Jimmy Yang.
"ORDER BY" AND "LIMIT BY" CLAUSE
PROBLEM:
When a 'limit' clause is specified in a query along with
group by and order by, optimizer chooses wrong index
there by examining more number of rows than required.
However without the 'limit' clause, optimizer chooses
the right index.
ANALYSIS:
With respect to the query specified, range optimizer chooses
the first index as there is a range present ( on 'a'). Optimizer
then checks for an index which would give records in sorted
order for the 'group by' clause.
While checking chooses the second index (on 'c,b,a') based on
the 'limit' specified and the selectivity of
'quick_condition_rows' (number of rows present in the range)
in 'test_if_skip_sort_order' function.
But, it fails to consider that an order by clause on a
different column will result in scanning the entire index and
hence the estimated number of rows calculated above are
wrong (which results in choosing the second index).
FIX:
Do not enforce the 'limit' clause in the call to
'test_if_skip_sort_order' if we are creating a temporary
table. Creation of temporary table indicates that there would be
more post-processing and hence will need all the rows.
This fix is backported from 5.6. This problem is fixed in 5.6 as
part of changes for work log #5558
mysql-test/r/subselect.result:
Changes for Bug#11762052 results in the correct number of rows.
sql/sql_select.cc:
Do not pass the actual 'limit' value if 'need_tmp' is true.
Now partition engine adds underlying tables to the QC and ask underlying tables engine permittion to cache the query and return result of the query.
Incorrect QC cleanup in case of table registration failure fixe.
Unified interface for myisammrg & partitioned engnes for QC.
rpl_cant_read_event_incident:
Slave applies updates from bug11747416_32228_binlog.000001 file which
contains a CREATE TABLE t statement and an incident, when SQL thread is
running slowly IO thread may reach the incident before SQL thread
executes the create table statement.
Execute "drop table if exists t" and also perform a RESET MASTER to
clean slave binary logs.
rpl_bug41902:
Error "MYSQL_BIN_LOG::purge_logs was called with file
./master-bin.000001 not listed in the index." suppression is not
considering windows path, there is ".\master-bin.000001".
Changed suppression to: "MYSQL_BIN_LOG::purge_logs was called with file
..master-bin.000001 not listed in the index", to match ".\" and "./".
This is a followup patch for the bug enabling the test
i_binlog.binlog_mysqlbinlog_file_write.test
this was disabled in mysql trunk and mysql 5.5 as in the release
build mysqlbinlog was not debug compiled whereas the mysqld was.
Since have_debug.inc script checks only for mysqld to be debug
compiled, the test was not being skipped on release builds.
We resolve this problem by creating a new inc file
mysqlbinlog_have_debug.inc which checks exclusively for mysqlbinlog
to be debug compiled. if not it skips the test.
mysql-test/include/mysqlbinlog_have_debug.inc:
new inc file to check if mysqlbinlog is debug compiled.
1. Clear text password client plugin disabled by default.
2. Added an environment variable LIBMYSQL_ENABLE_CLEARTEXT_PLUGIN, that
when set to something starting with '1', 'Y' or 'y' will enable the clear
text
plugin for all connections.
3. Added a new mysql_options() option : MYSQL_ENABLE_CLEARTEXT_PLUGIN
that takes an my_bool argument. When the value of the argument is non-zero
the clear text plugin is enabled for this connection only.
4. Added an enable-cleartext-plugin config file option that takes a numeric
argument. If the numeric value of the numeric argument is non-zero the
clear
text plugin is enabled for the connection
5. Added a boolean command line option "--enable_cleartext_plugin" to
mysql, mysqlslap and mysqladmin. When specified it will call mysql_options
with the effect of #3
6. Added a new CLEARTEXT option to the connect command in mysqltest.
When specified it will enable the cleartext plugin for usage.
7. Added test cases and updated existing ones that need the clear text
plugin.
executing
The problem is that mysql lacks information about the objects a view
depends on so it can't dump views and tables in the proper order.
Thus it needs to create "stand-in" myisam tables for each view while
dumping the tables that it later drops and replaces with the actual view
view definition.
But since views can have much more columns than an actual table creating
these stand-in tables may be problematic.
There's no way to portably find out how many columns an mysiam table
can have. It's a complicated formula depending on internal server constants.
Thus we can't have a reliable error check without repeating the logic and
the formula inside mysqldump.
1. Changed the type of the columns of the stand-in tables mysqldump
makes to satisfy view dependencies from the original type to smallint
to save on row space.
2. Added a warning on the mysqldump's standard error for a possible
problems replaying the dump file if the columns of a view exceed 1000.
3. Added a test case.
Print the warning(note):
YEAR(x) is deprecated and will be removed in a future release. Please use YEAR(4) instead
on "CREATE TABLE ... YEAR(x)" or "ALTER TABLE MODIFY ... YEAR(x)", where x != 4
- Better error messages
This fixes that one again can run the test systems with many threads without having to increase fs.aio-max-nr.
mysql-test/include/mtr_check.sql:
Ignore the INNODB_USE_NATIVE_AIO variable (may change during execution)
mysql-test/mysql-test-run.pl:
Ignore warnings for failure to setup AIO
storage/innobase/os/os0file.c:
Continue without AIO even if we can't allocate resources for AIO
storage/xtradb/os/os0file.c:
Continue without AIO even if we can't allocate resources for AIO
storage/xtradb/srv/srv0start.c:
Give an error message (instead of core dump) if AIO can't be initialized
TABLE_LIST::check_single_table made aware about fact that now if table attached to a merged view it can be (unopened) temporary table
(in 5.2 it was always leaf table or non (in case of several tables)).
the new file is fully synced to disk and binlog index. This fixes a window
where a crash would leave next server restart unable to detect that a crash
occured, causing recovery to fail.
We set correct cmp_context during preparation to avoid changing it later by Item_field::equal_fields_propagator.
(see mysql bugs #57135#57692 during merging)