Make show_create_table_ex/get_default_field_value() use
Field::real_maybe_null(), not maybe_null().
Before, the difference didn't matter as show_create_table_ex() was
only invoked in SHOW CREATE TABLE where columns are not made NULLable.
Optimizer context code invokes show_create_tableas show_create_table_ex()
in all queries, so now the distinction matters.
This task loads the stats of the tables that are used in a query,
from the trace into the optimizer. This feature is controlled
by optimizer_replay_context, and points to an user defined variable name,
that has the context information.
The stats such as num_of_records present in the table, indexes if present,
their names, along with the average number of records_per_key
with in each index, cost of reading an index are loaded from the trace.
Additionally, stats from range analysis i.e. ranges, and the
corresponding number of records, along with their costs are also
loaded from the trace.
The trace context which is in JSON format is firstly set into the
user defined session variable, and this variable name is set to
optimizer_replay_context system variable.
Later, when a user issues a query, the contents of the json context is
parsed and an in memory representation is built using the class
Optimizer_context_replay. This class is then used by the optimizer
to update and save original values of the tables, indexes, and range stats
in the methods "set_statistics_for_table()" of sql_statistics.cc, and
"check_quick_select()" of opt_range.cc.
After the query gets finished, the statistics that were updated
in the optimizer are restored back to the saved original values.
The entry point for parsing the json structure is in
"mysql_execute_command()" of sql_parse.cc, and similarly exit point
i.e. to restore the saved stats of the optimizer is at the end
of the same method.
Two new warning/error messages are introduced:
ER_JSON_OPTIMIZER_REPLAY_CONTEXT_PARSE_FAILED, and
ER_JSON_OPTIMIZER_REPLAY_CONTEXT_MATCH_FAILED
WITH GRANT OPTION is not a privilege in the standard sense,
so whenever INFORMATION_SCHEMA visibility dictates "any privilege"
this does not include WITH GRANT OPTION, even though GRANT_ACL
is a privilege in MariaDB.
Assisted-By: Claude:claude-4.6-sonnet
1.
Only allow #mysql50# prefix on table names that
can not be decoded from a file name to a table name.
It is an error to put this prefix on a name that can be accessed
as a valid table name without a prefix. Use `t1` not `#mysql50#t1`,
use `a-b` not `#mysql50#a@002db`.
2.
Don't allow creation of new tables with the #mysql50# prefix.
Except when in SQLCOM_ALTER_DB_UPGRADE - main.upgrade test runs
ALTER DATABASE `#mysql50#mysqltest-1` UPGRADE DATA DIRECTORY NAME;
This command moves tables from the old db name to the new db name,
and some of these tables also have old #mysql50# names.
3.
Also don't allow to create such databases, views, partitions,
subpartitions, sequences, triggers.
Three problems:
1. Option value specified as `foo bar` was not quoted,
printed as foo bar, breaking CREATE TABLE.
2. Option value that included */ was printed as is, in unknown
options when the whole option was commented out, this broke the
comment: /* opt='val*/ue' */
3. Option names can include */ too, `opt*/ion`=1
Fix: simplify value printing, ignore the original quoting, always
print the value quoted as a string. Break comment markers with an
escape (as *\/) if inside a comment. As \-escapes don't work inside,
backticks, we cannot use `-quoting for option values at all.
For the same reason we cannot allow */ inside option names, thus
let's only allow keywords for option names and reject fancy names
even if IGNORE_BAD_TABLE_OPTIONS is in force.
gcc 15.1.15 gives the following error, possible from static struct
initialization:
/my/maria-11.8/sql/sql_show.cc: In function ‘void __static_initialization_and_destruction_0()’:
/my/maria-11.8/sql/sql_show.cc:11356:1: error: the frame size of 62880 bytes is larger than 16384 bytes [-Werror=frame-larger-than=]
Fixed by adding PRAGMA_DISABLE_CHECK_STACK_FRAME to sql_show.cc
This patch implements support for implicit query block (QB) names in
optimizer hints, allowing hints to reference query blocks and tables
within derived tables, views and CTEs without requiring explicit
QB_NAME hints.
Examples.
-- Addressing a table inside a derived table using implicit QB name
select /*+ no_index(t1@dt) */ *
from (select * from t1 where a > 10) as DT;
-- this is an equivalent to:
select /*+ no_index(t1@dt) */ * from
(select /*+ qb_name(dt)*/ * from t1 where a > 10) as DT;
-- Addressing a query block corresponding to the derived table
select /*+ no_bnl(@dt) */ *
from (select * from t1, t2 where t.1.a > t2.a) as DT;
-- View
create view v1 as select * from t1 where a > 10 and b > 100;
-- referencing a table inside a view by implicit QB name:
select /*+ index_merge(t1@v1 idx_a, idx_b) */ *
from v1, t2 where v1.a = t2.a;
-- equivalent to:
create view v1 as select /*+ qb_name(qb_v1) */ *
from t1 where a > 10 and b > 100;
select /*+ index_merge(t1@qb_v1 idx_a, idx_b) */ *
from v1, t2 where v1.a = t2.a;
-- CTE
with aless100 as (select a from t1 where b <100)
select /*+ index(t1@aless100) */ * from aless100;
-- equivalent to:
with aless100 as (select /*+ qb_name(aless100) */ a from t1 where b <100)
select /*+ index(t1@aless100) */ * from aless100;
Limitations:
- Only SELECT statements support implicit QB names. DML operations
(UPDATE, DELETE, INSERT) only support explicit QB names
Vector indexes are stored in a separate internal table (hlindex).
The main table's storage engine knows nothing about it, INDEX_LENGTH
was always reported as 0 for tables with vector indexes.
the fix: after calling info() on the main table handler in sql_show.cc,
check if the table has an hlindex, open it if needed, and add its data_file_length to
index_file_length before writing to the information schema record.
Problem:
UBSAN reports runtime errors in string comparision functions when
pointer arithmetic is done without checking NULL.
Fix:
- Add debug asserts in `strnncoll` function to catch NULL pointers.
- Define a new function `streq_safe` as a replacement for `streq`,
capable of handling NULL pointers. Replace `streq` with `streq_safe`
at multiple call sites, identified by the debug asserts.
- Add empty identifier checks in `is_infoschema_db` and
`is_perfschema_db` before calling the deep character-set based
comparision.
- Add IS_DEPRECATED and DEPRECATION_REPLACEMENT columns to the
SYSTEM_VARIABLES information schema table
- Add a mysql-test case to verify the new columns output correctly
gcc 15.1.15 gives the following error, possible from static struct
initialization:
/my/maria-11.8/sql/sql_show.cc: In function ‘void __static_initialization_and_destruction_0()’:
/my/maria-11.8/sql/sql_show.cc:11356:1: error: the frame size of 62880 bytes is larger than 16384 bytes [-Werror=frame-larger-than=]
Fixed by adding PRAGMA_DISABLE_CHECK_STACK_FRAME to sql_show.cc
paritioning has its own method for printing engine options,
it wasn't consistent with how table options were printed - didn't
use quotes, ignored sql_mode, so wasn't future and dump/import safe.
let's get rid of it and use the same method that prints per-table
engine options.
let's simplify the code by removing copying of part_elem->connect_string
to table->s->connect_string. Move CONNECTION support from he server into
engines, engines define TOPTION("CONNECTION") if they want to support it,
it's stored in the option_struct and handled by the option_struct fix.
Problems:
* Mroonga used CONNECTION for something but there were no tests for it.
Removed Mroonga support for CONNECTION as requested by the maintainer
in MDEV-38530
* DROP/ALTER SERVER command used to close all tables using the server
in question, avoiding the need for FLUSH TABLES. This functionality
never worked for partitioned tables anyway and is now removed. Will be
done properly in MDEV-37827.
some I_S tables require "any non-SELECT privilege on the table".
If only SELECT was granted on the global level and something non-SELECT
on the schema level, then we need to check schema level privileges
explicitly, because check_grant() doesn't do that and get_all_tables()
doesn't look deeper if SELECT is present on the global level.
According to SQL standard, rows from `INFORMATION_SCHEMA.TRIGGERS` table
should be visible to users with non-SELECT privileges on the columns.
`ACTION_CONDITION`, `ACTION_STATEMENT` and `DEFINER` columns should be
visible only if the user is the owner of the schema.
MariaDB uses `TRIGGER` privilege instead of owner, which controls the
visibilty of all columns, including those which only need non-SELECT
privileges.
This fix
- Allows users with non-SELECT privileges- INSERT, DELETE or UPDATE,
to see rows in `INFORMATION_SCHEMA.TRIGGERS` table.
- Ensure `ACTION_CONDITION`, `ACTION_STATEMENT` and `DEFINER` columns
are `NULL` unless the user is the owner of the schema or has `TRIGGER`
privilege.
Setting a name for the the THD::security_ctx:user field for wsrep applier threads.
With this, the audit log events related to wsrep applying will be written in the
audit log.
Using user name <wsrep_applier> for wsrep appliers. This is for having identical
look with async replication, which uses: <replication_slave> for audit logging.
Using same approach as async replication to replace the security_ctx user name
with "system user" for processlist output.
Commit has also a mtr test galera.MDEV-35511, to verify wsrep applier audit logging.
The test does not install/uninstall audit log plugin, but loads the audit log plugin
before the test. This is because uninstalling the audit log plugin gives a warning
saying that plugin is busy and uninstall will be delayed until server shutdown.
This anomaly must be because of the applier thread being active audit logger.
Same problem with plugin uninstall happens also with async relication workers.
If plugn would remain installed, the post test sanity check complains of mismatching
state of pre and post test states, and test execution would fail for this.