Backport Bug #45827 Stmt using two autoinc values does not produce unsafe warning
One statement that have more than one different tables to update with autoinc columns just was marked as unsafe in mixed mode, so the unsafe warning can't be produced in statement mode. To fix the problem, mark the statement as unsafe in statement mode too.
This commit is contained in:
@ -5286,9 +5286,7 @@ int lock_tables(THD *thd, TABLE_LIST *tables, uint count, bool *need_reopen)
|
||||
We can solve these problems in mixed mode by switching to binlogging
|
||||
if at least one updated table is used by sub-statement
|
||||
*/
|
||||
/* The BINLOG_FORMAT_MIXED judgement is saved for suppressing
|
||||
warnings, but it will be removed by fixing bug#45827 */
|
||||
if (thd->variables.binlog_format == BINLOG_FORMAT_MIXED && tables &&
|
||||
if (thd->variables.binlog_format != BINLOG_FORMAT_ROW && tables &&
|
||||
has_write_table_with_auto_increment(thd->lex->first_not_own_table()))
|
||||
{
|
||||
thd->lex->set_stmt_unsafe();
|
||||
|