1
0
mirror of https://github.com/MariaDB/server.git synced 2025-07-29 05:21:33 +03:00

BUG#49019 Mixing self-logging eng. and regular eng. does not switch to row in mixed mode

Reading from a self-logging engine and updating a transactional engine such as Innodb
generates changes that are written to the binary log in the statement format and may
make slaves diverge. In the mixed mode, such changes should be written to the binary
log in the row format.

Note that the issue does not happen if we mix a self-logging engine and MyIsam
as this case is caught by checking the mixture of non-transactional and transactional
engines.

So, we classify a mixed statement where one reads from NDB and writes into another 
engine as unsafe:

if (multi_engine && flags_some_set & HA_HAS_OWN_BINLOGGING)
  lex->set_stmt_unsafe(LEX::BINLOG_STMT_UNSAFE_MULTIPLE_ENGINES_AND_SELF_LOGGING_ENGINE);
This commit is contained in:
Alfranio Correia
2010-02-22 03:25:33 +00:00
parent 36d6330aa1
commit 7194aec8ba
6 changed files with 100 additions and 27 deletions

View File

@ -3587,12 +3587,14 @@ int THD::decide_logging_format(TABLE_LIST *tables)
capabilities, and one with the intersection of all the engine
capabilities.
*/
handler::Table_flags flags_write_some_set= 0;
handler::Table_flags flags_some_set= 0;
handler::Table_flags flags_all_set=
handler::Table_flags flags_write_all_set=
HA_BINLOG_ROW_CAPABLE | HA_BINLOG_STMT_CAPABLE;
my_bool multi_write_engine= FALSE;
my_bool multi_engine= FALSE;
my_bool mixed_engine= FALSE;
my_bool trans_non_trans_multi_engine= FALSE;
my_bool all_trans_engines= TRUE;
TABLE* prev_write_table= NULL;
TABLE* prev_access_table= NULL;
@ -3619,26 +3621,42 @@ int THD::decide_logging_format(TABLE_LIST *tables)
continue;
if (table->table->s->table_category == TABLE_CATEGORY_PERFORMANCE)
lex->set_stmt_unsafe(LEX::BINLOG_STMT_UNSAFE_SYSTEM_TABLE);
handler::Table_flags const flags= table->table->file->ha_table_flags();
DBUG_PRINT("info", ("table: %s; ha_table_flags: 0x%llx",
table->table_name, flags));
if (table->lock_type >= TL_WRITE_ALLOW_WRITE)
{
handler::Table_flags const flags= table->table->file->ha_table_flags();
DBUG_PRINT("info", ("table: %s; ha_table_flags: 0x%llx",
table->table_name, flags));
if (prev_write_table && prev_write_table->file->ht !=
table->table->file->ht)
multi_engine= TRUE;
multi_write_engine= TRUE;
all_trans_engines= all_trans_engines &&
table->table->file->has_transactions();
prev_write_table= table->table;
flags_all_set &= flags;
flags_some_set |= flags;
flags_write_all_set &= flags;
flags_write_some_set |= flags;
}
flags_some_set |= flags;
if (prev_access_table && prev_access_table->file->ht != table->table->file->ht)
mixed_engine= mixed_engine || (prev_access_table->file->has_transactions() !=
table->table->file->has_transactions());
{
multi_engine= TRUE;
trans_non_trans_multi_engine= trans_non_trans_multi_engine ||
(prev_access_table->file->has_transactions() !=
table->table->file->has_transactions());
}
prev_access_table= table->table;
}
DBUG_PRINT("info", ("flags_write_all_set: 0x%llx", flags_write_all_set));
DBUG_PRINT("info", ("flags_write_some_set: 0x%llx", flags_write_some_set));
DBUG_PRINT("info", ("flags_some_set: 0x%llx", flags_some_set));
DBUG_PRINT("info", ("multi_write_engine: %d", multi_write_engine));
DBUG_PRINT("info", ("multi_engine: %d", multi_engine));
DBUG_PRINT("info", ("trans_non_trans_multi_engine: %d",
trans_non_trans_multi_engine));
int error= 0;
int unsafe_flags;
/*
Set the statement as unsafe if:
@ -3708,32 +3726,25 @@ int THD::decide_logging_format(TABLE_LIST *tables)
isolation level but if we have pure repeatable read or serializable the
lock history on the slave will be different from the master.
*/
if (mixed_engine ||
if (trans_non_trans_multi_engine ||
(trans_has_updated_trans_table(this) && !all_trans_engines))
lex->set_stmt_unsafe(LEX::BINLOG_STMT_UNSAFE_NONTRANS_AFTER_TRANS);
DBUG_PRINT("info", ("flags_all_set: 0x%llx", flags_all_set));
DBUG_PRINT("info", ("flags_some_set: 0x%llx", flags_some_set));
DBUG_PRINT("info", ("multi_engine: %d", multi_engine));
int error= 0;
int unsafe_flags;
/*
If more than one engine is involved in the statement and at
least one is doing it's own logging (is *self-logging*), the
statement cannot be logged atomically, so we generate an error
rather than allowing the binlog to become corrupt.
*/
if (multi_engine &&
(flags_some_set & HA_HAS_OWN_BINLOGGING))
{
if (multi_write_engine &&
(flags_write_some_set & HA_HAS_OWN_BINLOGGING))
my_error((error= ER_BINLOG_MULTIPLE_ENGINES_AND_SELF_LOGGING_ENGINE),
MYF(0));
}
else if (multi_engine && flags_some_set & HA_HAS_OWN_BINLOGGING)
lex->set_stmt_unsafe(LEX::BINLOG_STMT_UNSAFE_MULTIPLE_ENGINES_AND_SELF_LOGGING_ENGINE);
/* both statement-only and row-only engines involved */
if ((flags_all_set & (HA_BINLOG_STMT_CAPABLE | HA_BINLOG_ROW_CAPABLE)) == 0)
if ((flags_write_all_set & (HA_BINLOG_STMT_CAPABLE | HA_BINLOG_ROW_CAPABLE)) == 0)
{
/*
1. Error: Binary logging impossible since both row-incapable
@ -3742,7 +3753,7 @@ int THD::decide_logging_format(TABLE_LIST *tables)
my_error((error= ER_BINLOG_ROW_ENGINE_AND_STMT_ENGINE), MYF(0));
}
/* statement-only engines involved */
else if ((flags_all_set & HA_BINLOG_ROW_CAPABLE) == 0)
else if ((flags_write_all_set & HA_BINLOG_ROW_CAPABLE) == 0)
{
if (lex->is_stmt_row_injection())
{
@ -3790,7 +3801,7 @@ int THD::decide_logging_format(TABLE_LIST *tables)
*/
my_error((error= ER_BINLOG_ROW_INJECTION_AND_STMT_MODE), MYF(0));
}
else if ((flags_all_set & HA_BINLOG_STMT_CAPABLE) == 0)
else if ((flags_write_all_set & HA_BINLOG_STMT_CAPABLE) == 0)
{
/*
5. Error: Cannot modify table that uses a storage engine
@ -3818,7 +3829,7 @@ int THD::decide_logging_format(TABLE_LIST *tables)
else
{
if (lex->is_stmt_unsafe() || lex->is_stmt_row_injection()
|| (flags_all_set & HA_BINLOG_STMT_CAPABLE) == 0)
|| (flags_write_all_set & HA_BINLOG_STMT_CAPABLE) == 0)
{
/* log in row format! */
set_current_stmt_binlog_format_row_if_mixed();