MCOL-4839: Fix clang build (#2100)
* Fix clang build * Extern C returned to plugin_instance Co-authored-by: Leonid Fedorov <l.fedorov@mail.corp.ru>
This commit is contained in:
@@ -1378,7 +1378,7 @@ DataConvert::StringToUDecimal(const datatypes::SystemCatalog::TypeAttributesStd&
|
||||
const std::string& data, bool& pushWarning)
|
||||
{
|
||||
const cscDataType typeCode= datatypes::SystemCatalog::UDECIMAL;
|
||||
|
||||
|
||||
// UDECIMAL numbers may not be negative
|
||||
if (LIKELY(colType.colWidth == 16))
|
||||
{
|
||||
@@ -1532,8 +1532,8 @@ DataConvert::StringToFloat(cscDataType typeCode,
|
||||
|
||||
if (floatvalue < 0.0 &&
|
||||
typeCode == datatypes::SystemCatalog::UFLOAT &&
|
||||
floatvalue != joblist::FLOATEMPTYROW &&
|
||||
floatvalue != joblist::FLOATNULL)
|
||||
floatvalue != static_cast<float>(joblist::FLOATEMPTYROW) &&
|
||||
floatvalue != static_cast<float>(joblist::FLOATNULL))
|
||||
{
|
||||
value = 0.0; // QQ: should it assign floatvalue?
|
||||
pushWarning = true;
|
||||
@@ -1595,8 +1595,8 @@ DataConvert::StringToDouble(cscDataType typeCode,
|
||||
|
||||
if (doublevalue < 0.0 &&
|
||||
typeCode == datatypes::SystemCatalog::UDOUBLE &&
|
||||
doublevalue != joblist::DOUBLEEMPTYROW &&
|
||||
doublevalue != joblist::DOUBLENULL)
|
||||
doublevalue != static_cast<double>(joblist::DOUBLEEMPTYROW) &&
|
||||
doublevalue != static_cast<double>(joblist::DOUBLENULL))
|
||||
{
|
||||
doublevalue = 0.0; // QQ: should it assign "value" ?
|
||||
pushWarning = true;
|
||||
|
Reference in New Issue
Block a user