Fully resolve potentially ambiguous symbols by removing using namespace statements from headers which have a cascading effect. This causes potential behavior changes when switching to c++11 since symbols can be exported from std and boost while both have been imported into the global namespace.
This commit is contained in:
@ -51,11 +51,7 @@
|
||||
#define EXPORT
|
||||
#endif
|
||||
|
||||
using namespace std;
|
||||
using namespace execplan;
|
||||
|
||||
#include <boost/algorithm/string/case_conv.hpp>
|
||||
using namespace boost::algorithm;
|
||||
|
||||
template <class T>
|
||||
bool from_string(T& t,
|
||||
@ -72,7 +68,7 @@ struct DDLColumn
|
||||
{
|
||||
execplan::CalpontSystemCatalog::OID oid;
|
||||
execplan::CalpontSystemCatalog::ColType colType;
|
||||
execplan:: CalpontSystemCatalog::TableColName tableColName;
|
||||
execplan::CalpontSystemCatalog::TableColName tableColName;
|
||||
};
|
||||
|
||||
typedef std::vector<DDLColumn> ColumnList;
|
||||
@ -104,23 +100,23 @@ inline void getColumnsForTable(uint32_t sessionID, std::string schema, std::str
|
||||
ColumnList& colList)
|
||||
{
|
||||
|
||||
CalpontSystemCatalog::TableName tableName;
|
||||
execplan::CalpontSystemCatalog::TableName tableName;
|
||||
tableName.schema = schema;
|
||||
tableName.table = table;
|
||||
std::string err;
|
||||
|
||||
try
|
||||
{
|
||||
boost::shared_ptr<CalpontSystemCatalog> systemCatalogPtr = CalpontSystemCatalog::makeCalpontSystemCatalog(sessionID);
|
||||
systemCatalogPtr->identity(CalpontSystemCatalog::EC);
|
||||
boost::shared_ptr<execplan::CalpontSystemCatalog> systemCatalogPtr = execplan::CalpontSystemCatalog::makeCalpontSystemCatalog(sessionID);
|
||||
systemCatalogPtr->identity(execplan::CalpontSystemCatalog::EC);
|
||||
|
||||
const CalpontSystemCatalog::RIDList ridList = systemCatalogPtr->columnRIDs(tableName);
|
||||
const execplan::CalpontSystemCatalog::RIDList ridList = systemCatalogPtr->columnRIDs(tableName);
|
||||
|
||||
CalpontSystemCatalog::RIDList::const_iterator rid_iterator = ridList.begin();
|
||||
execplan::CalpontSystemCatalog::RIDList::const_iterator rid_iterator = ridList.begin();
|
||||
|
||||
while (rid_iterator != ridList.end())
|
||||
{
|
||||
CalpontSystemCatalog::ROPair roPair = *rid_iterator;
|
||||
execplan::CalpontSystemCatalog::ROPair roPair = *rid_iterator;
|
||||
|
||||
DDLColumn column;
|
||||
column.oid = roPair.objnum;
|
||||
@ -381,112 +377,112 @@ inline int convertDataType(int dataType)
|
||||
switch (dataType)
|
||||
{
|
||||
case ddlpackage::DDL_CHAR:
|
||||
calpontDataType = CalpontSystemCatalog::CHAR;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::CHAR;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_VARCHAR:
|
||||
calpontDataType = CalpontSystemCatalog::VARCHAR;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::VARCHAR;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_VARBINARY:
|
||||
calpontDataType = CalpontSystemCatalog::VARBINARY;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::VARBINARY;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_BIT:
|
||||
calpontDataType = CalpontSystemCatalog::BIT;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::BIT;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_REAL:
|
||||
case ddlpackage::DDL_DECIMAL:
|
||||
case ddlpackage::DDL_NUMERIC:
|
||||
case ddlpackage::DDL_NUMBER:
|
||||
calpontDataType = CalpontSystemCatalog::DECIMAL;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::DECIMAL;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_FLOAT:
|
||||
calpontDataType = CalpontSystemCatalog::FLOAT;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::FLOAT;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_DOUBLE:
|
||||
calpontDataType = CalpontSystemCatalog::DOUBLE;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::DOUBLE;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_INT:
|
||||
case ddlpackage::DDL_INTEGER:
|
||||
calpontDataType = CalpontSystemCatalog::INT;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::INT;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_BIGINT:
|
||||
calpontDataType = CalpontSystemCatalog::BIGINT;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::BIGINT;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_MEDINT:
|
||||
calpontDataType = CalpontSystemCatalog::MEDINT;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::MEDINT;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_SMALLINT:
|
||||
calpontDataType = CalpontSystemCatalog::SMALLINT;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::SMALLINT;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_TINYINT:
|
||||
calpontDataType = CalpontSystemCatalog::TINYINT;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::TINYINT;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_DATE:
|
||||
calpontDataType = CalpontSystemCatalog::DATE;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::DATE;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_DATETIME:
|
||||
calpontDataType = CalpontSystemCatalog::DATETIME;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::DATETIME;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_TIME:
|
||||
calpontDataType = CalpontSystemCatalog::TIME;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::TIME;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_CLOB:
|
||||
calpontDataType = CalpontSystemCatalog::CLOB;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::CLOB;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_BLOB:
|
||||
calpontDataType = CalpontSystemCatalog::BLOB;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::BLOB;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_TEXT:
|
||||
calpontDataType = CalpontSystemCatalog::TEXT;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::TEXT;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_UNSIGNED_TINYINT:
|
||||
calpontDataType = CalpontSystemCatalog::UTINYINT;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::UTINYINT;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_UNSIGNED_SMALLINT:
|
||||
calpontDataType = CalpontSystemCatalog::USMALLINT;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::USMALLINT;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_UNSIGNED_MEDINT:
|
||||
calpontDataType = CalpontSystemCatalog::UMEDINT;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::UMEDINT;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_UNSIGNED_INT:
|
||||
calpontDataType = CalpontSystemCatalog::UINT;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::UINT;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_UNSIGNED_BIGINT:
|
||||
calpontDataType = CalpontSystemCatalog::UBIGINT;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::UBIGINT;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_UNSIGNED_DECIMAL:
|
||||
case ddlpackage::DDL_UNSIGNED_NUMERIC:
|
||||
calpontDataType = CalpontSystemCatalog::UDECIMAL;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::UDECIMAL;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_UNSIGNED_FLOAT:
|
||||
calpontDataType = CalpontSystemCatalog::UFLOAT;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::UFLOAT;
|
||||
break;
|
||||
|
||||
case ddlpackage::DDL_UNSIGNED_DOUBLE:
|
||||
calpontDataType = CalpontSystemCatalog::UDOUBLE;
|
||||
calpontDataType = execplan::CalpontSystemCatalog::UDOUBLE;
|
||||
break;
|
||||
|
||||
default:
|
||||
|
Reference in New Issue
Block a user