MCOL-641 atoi128 now correctly processes decimal point and - signs.
There are multiple overloaded version of the low level DML write methods to push down CSC column type. WE needs the type to convert values correctly. Replaced WE_INT128 with CSC data type that is more informative. Removed commented and obsolete code. Replaced switch-case blocks with oneliners.
This commit is contained in:
@ -639,7 +639,8 @@ void Convertor::convertColType(ColStruct* curStruct)
|
||||
|
||||
default:
|
||||
// WIP replace with BINARY
|
||||
*internalType = WriteEngine::WR_INT128;
|
||||
//*internalType = WriteEngine::WR_INT128;
|
||||
*internalType = WriteEngine::WR_BINARY;
|
||||
break;
|
||||
}
|
||||
|
||||
|